Identification des équipements critiques et détermination des limites de fonctionnement dans les réfrigérateurs à hélium sous charge thermique pulsée.

Identification of critical equipment and determination of operational limits in helium refrigerators under pulsed heat load.

Auteurs : DUTTA R., GHOSH P., CHOWDHURY K.

Type d'article : Article

Résumé

Large-scale helium refrigerators are subjected to pulsed heat load from tokamaks. As these plants are designed for constant heat loads, operation under such varying load may lead to instability in plants thereby tripping the operation of different equipment. To understand the behavior of the plant subjected to pulsed heat load, an existing plant of 120 W at 4.2 K and another large-scale plant of 18 kW at 4.2 K have been analyzed using a commercial process simulator Aspen Hysys®. A similar heat load characteristic has been applied in both quasi steady state and dynamic analysis to determine critical stages and equipment of these plants from operational point of view. It has been found that the coldest part of both the cycles consisting JT-stage and its preceding reverse Brayton stage are the most affected stages of the cycles. Further analysis of the above stages and constituting equipment revealed limits of operation with respect to variation of return stream flow rate resulted from such heat load variations. The observations on the outcome of the analysis can be used for devising techniques for steady operation of the plants subjected to pulsed heat load.

Détails

  • Titre original : Identification of critical equipment and determination of operational limits in helium refrigerators under pulsed heat load.
  • Identifiant de la fiche : 30011429
  • Langues : Anglais
  • Source : Cryogenics - vol. 59
  • Date d'édition : 01/2014
  • DOI : http://dx.doi.org/10.1016/j.cryogenics.2013.12.005

Liens


Voir d'autres articles du même numéro (7)
Voir la source