A simple model for falling film absorption on vertical tubes in the presence of non-absorbables.
A simple model for falling film absorption on vertical tubes in the presence of non-absorbables.
Auteurs : MEDRANO M., BOUROUIS M., PEREZ-BLANCO H., et al.
Type d'article : Article, Article de la RIF
Résumé
Most water-lithium bromide (LiBr) absorption chillers have a purge system to remove non-absorbable gases that cause a reduction in cooling capacity. Generally, the non-absorbables are originated in corrosion/passivation processes inside the machine, but leaks can also be a source of concern. However, since leaks must be corrected immediately to avoid machine deterioration, this study is mostly aimed at the non-absorbables evolved during operation. This paper analyses the effect of inlet non-absorbable air concentration, outlet purge velocity, absorber pressure and cooling water temperature on the falling film absorption process inside a vertical tube absorber, based on a simple transport coefficient model. This model consists of three ordinary differential equations solved with as method for initial-value problem, and a set of auxiliary equations. The study shows that the effect of non-absorbables can be significant, and furthermore provides a quantitative framework to aid in purge design. The nominal working conditions in this study were a solution Reynolds number of 100, an absorber pressure of 1.3 kPa, a cooling water temperature of 35 °C and an inlet solution concentration of 62% LiBr by weight. The results indicate that a minimum vapour velocity is required to sweep the non-absorbables along the absorber towards the purge, thus preventing reduced absorption fluxes. At a cooling water temperature of 35 °C, an inlet air concentration of 20% (by mole) resulted in a 61% reduction in mass absorption flux.
Documents disponibles
Format PDF
Pages : 108-116
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A simple model for falling film absorption on vertical tubes in the presence of non-absorbables.
- Identifiant de la fiche : 2003-1803
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 26 - n. 1
- Date d'édition : 01/2003
Liens
Voir d'autres articles du même numéro (14)
Voir la source
Indexation
- Thèmes : Systèmes à absorption et adsorption
- Mots-clés : Tube vertical; Système à absorption; Absorption; Modélisation; Gaz non condensable; Film tombant; Absorbeur
-
Non-absorbable gas effect on the wavy film abso...
- Auteurs : YANG R., JOU T. M.
- Date : 11/1998
- Langues : Anglais
- Source : International Journal of Heat and Mass Transfer - vol. 41 - n. 22
Voir la fiche
-
The effect of non-absorbable gas on an absorpti...
- Auteurs : YANG R., JOU T. M.
- Date : 03/2001
- Langues : Anglais
- Source : International Journal of Heat and Mass Transfer - vol. 44 - n. 6
Voir la fiche
-
Numericno simuliranje delovanja hlajenih absorb...
- Auteurs : PFLÜGL M.
- Date : 07/1998
- Langues : Slovène
- Source : Strojniski vestnik - Journal of mechanical Engineering - vol. 44 - n. 7-8
Voir la fiche
-
A realistic approach to modelling of LiBr-H2O s...
- Auteurs : ROGDAKIS E. D., PAPAEFTHIMIOU V. D., KARAMPINOS D. C.
- Date : 12/2003
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 23 - n. 17
Voir la fiche
-
Purge needs in absorption chillers.
- Auteurs : MURRAY J. G.
- Date : 10/1993
- Langues : Anglais
- Source : ASHRAE Journal - vol. 35 - n. 10
Voir la fiche