Allongement sur le long terme d'une fibre unique de Kevlar-49 à basse température.

Long term elongation of Kevlar-49 single fiber at low temperature.

Auteurs : BERSANI A., CANONICA L., CARIELLO M., et al.

Type d'article : Article

Résumé

We have measured the rate of elongation of a loaded Kevlar-49 fiber as a function of time at 4.2 K. The result puts a worst case upper limit of 0.028% in the elongation rate ?L/L for a 0.5 mm diameter fiber kept under a constant tension of 2.7 kg for 8 months. A value that is probably closer to reality is actually 0.004%. This result proves that Kevlar-49 can be safely used in cryogenic applications in which high mechanical stability under stress is required.

Détails

  • Titre original : Long term elongation of Kevlar-49 single fiber at low temperature.
  • Identifiant de la fiche : 30007947
  • Langues : Anglais
  • Source : Cryogenics - vol. 54
  • Date d'édition : 02/2013
  • DOI : http://dx.doi.org/10.1016/j.cryogenics.2012.10.005

Liens


Voir d'autres articles du même numéro (5)
Voir la source