Document IIF

Amélioration de la performance d'un cryorefroidisseur à pulsation fonctionnant à 4 K.

Increase in performance of a 4 K pulse tube cryocooler.

Auteurs : REVEX A., TROLLIER T., TANCHON J., et al.

Résumé

The helium enthalpy variation with temperature and pressure in the operating range of 4 K cryocoolers is by far different from ideal gas. This real gas behaviour leads to large irreversibility in regenerator operation. It is theoretically possible to reduce these losses and recover some "free" cooling power by implementing heat intercepts in the regenerator. The authors have experimentally confirmed this opportunity with a commercial 4 K pulse tube. Several hundred mW of "free" cooling power in the temperature range of 6 to 20 K have been obtained without any degradation in the initial cooling power at 4 K. The experimental set up is described and experimental results presented and discussed.

Documents disponibles

Format PDF

Pages : 2006-3/ICEC III-C3

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Increase in performance of a 4 K pulse tube cryocooler.
  • Identifiant de la fiche : 2008-1040
  • Langues : Anglais
  • Source : Multiconference CryoPrague 2006 (9th Cryogenics 2006, ICEC 21, ICMC'06)
  • Date d'édition : 17/07/2006

Liens


Voir d'autres communications du même compte rendu (142)
Voir le compte rendu de la conférence