In this research, the critical heat flux due to flooding limit of thermosiphon heat pipe using triethylene glycol (TEG)-water mixture was investigated. It was found that the use of a TEG-water mixture can extend the heat transport limitation compared with pure water and higher heat transfer is obtained compared with pure TEG in high temperature applications. The performances are presented and discussed.