Amélioration du transfert de chaleur des rainures transversales avec une prise en considération de l'effet d'entrée.

Heat transfer enhancement of transverse ribs in circular tubes with consideration of entrance effect.

Auteurs : SAN J. Y., HUANG W. C.

Type d'article : Article

Résumé

The heat transfer enhancement of transverse ribs in circular tubes with a length-to-diameter ratio of 87 was experimentally investigated. The mean heat transfer and friction data were obtained for the air flow started from the entrance. An isothermal surface condition was considered. The rib pitch-to-tube diameter ratio was in the range 0.304-5.72; the rib height-to-tube diameter ratio was in the range 0.015-0.143; the considered Reynolds number was in the range 4608-12,936. [Reprinted with permission from Elsevier. Copyright, 2006].

Détails

  • Titre original : Heat transfer enhancement of transverse ribs in circular tubes with consideration of entrance effect.
  • Identifiant de la fiche : 2007-0126
  • Langues : Anglais
  • Source : International Journal of Heat and Mass Transfer - vol. 49 - n. 17-18
  • Date d'édition : 08/2006

Liens


Voir d'autres articles du même numéro (14)