In this study, a 3D transient flow model of a scroll refrigeration compressor was established. To optimize a HVAC scroll compressor design for better energy efficiency and reliability, an understanding of the detailed mechanism of the unsteady refrigerant flow (R134A and R410A) is essential. Dynamic mesh / grids were generated and updated during the solving process to ensure better simulation results. The simulated results were validated with available standard manufacturer data. Furthermore, the flow mechanism and characteristic under a pressure ratio were analyzed in detail. The asymmetrical distributions of the parameters and vortexes were mainly caused by the asymmetrical suction flow passage and movement of the orbiting scroll. Special flow phenomena such as ‘cut-off’ led to a sharp decrease of the suction mass flux. The leakage flow resulted in inhomogeneous temperature and velocity distributions in the working chamber. The influence of leakage flow on the pressure distribution was weaker than temperature distribution.
Documents disponibles
Format PDF
Pages : 4
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance analysis by CFD of scroll compressor: using two high pressure refrigerants (R134A and R410A).
- Identifiant de la fiche : 30024784
- Langues : Anglais
- Source : Proceedings of the International Conference on Emerging Technologies for Sustainable and Intelligent HVAC&R Systems, Kolkata, July 27-28 2018.
- Date d'édition : 27/07/2018
Liens
Voir d'autres communications du même compte rendu (29)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Compresseurs;
HFC - Mots-clés : R410A; R134a; CFD; Simulation; Haute pression; Écoulement; Frigorigène; Conditionnement d'air; Compresseur à spirale
-
CFD analysis of high pressure compressor: compa...
- Auteurs : ADHIKARY P., IQBAL F., SADRI R., et al.
- Date : 27/07/2018
- Langues : Anglais
- Source : Proceedings of the International Conference on Emerging Technologies for Sustainable and Intelligent HVAC&R Systems, Kolkata, July 27-28 2018.
- Formats : PDF
Voir la fiche
-
CFD analysis of HVAC scroll compressor performa...
- Auteurs : ADHIKARY P., BANDYOPADHYAY S., MAZUMDAR A.
- Date : 27/07/2018
- Langues : Anglais
- Source : Proceedings of the International Conference on Emerging Technologies for Sustainable and Intelligent HVAC&R Systems, Kolkata, July 27-28 2018.
- Formats : PDF
Voir la fiche
-
Rotary compressor performance analysis comparis...
- Auteurs : ADHIKARY P., BANDYOPADHYAY S., MAZUMDAR A.
- Date : 27/07/2018
- Langues : Anglais
- Source : Proceedings of the International Conference on Emerging Technologies for Sustainable and Intelligent HVAC&R Systems, Kolkata, July 27-28 2018.
- Formats : PDF
Voir la fiche
-
Methods of fluid properties for compressible re...
- Auteurs : BRANCH S. M.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 22nd International Compressor Engineering Conference at Purdue.
- Formats : PDF
Voir la fiche
-
I compressori scroll e i nuovi fluidi.
- Auteurs : SERVIZI F.
- Date : 2002
- Langues : Italien
- Source : Industria & Formazione - vol. 26 - n. 255
Voir la fiche