Document IIF
Analyse d'un éjecteur pour un réfrigérateur domestique.
Ejector analysis for domestic refrigerator.
Numéro : pap. ID: 906
Auteurs : TULAPURKAR C., TAMMA B.
Résumé
Ejector is one of the pressure recovery devices having the advantage of no moving parts and simpler construction. The ejector feasibility for a domestic refrigerator with cooling capacity in the range of 240 W has rarely been reported in the literature either theoretically or experimentally. The main objective of this study is to predict the change in the Energy Efficiency Ratio (EER) of the sealed system of the domestic refrigerator with an ejector added in the suction side of the sealed system. In the current work, a mathematical model for the ejector has been developed and integrated with the system level model developed for the vapour compression cycle of a domestic refrigerator. The ejector model is based on one-dimensional mass, momentum and energy balance. Nozzle, mixing section and diffuser are modelled separately. Entrainment ratio at the nozzle exit is iterated based on vapour quality of the resultant stream. A compressor model based on pressure ratio and vapour compression cycle state points is incorporated to predict EER. The developed model is used to optimize area ratio for maximum EER improvement for the given domestic refrigerator application. The results from the model shows that approximately 5% of EER improvement is possible in a domestic refrigerator with an ejector having nozzle efficiency more than 60% and diffuser efficiency more than 85%.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Ejector analysis for domestic refrigerator.
- Identifiant de la fiche : 30001638
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Date d'édition : 21/08/2011
Liens
Voir d'autres communications du même compte rendu (569)
Voir le compte rendu de la conférence
-
Performance analysis of a compression-ejection ...
- Auteurs : ELAKHDAR M., NEHDI E., KAIROUANI L.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Operational characteristics of Stirling machinery.
- Auteurs : KWON Y. R., BERCHOWITZ D. M.
- Date : 17/08/2003
- Langues : Anglais
- Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
Voir la fiche
-
Maximized performance of Stirling cycle refrige...
- Auteurs : BERCHOWITZ D. M.
- Date : 02/06/1998
- Langues : Anglais
- Source : Natural Refrigerants, Energy Efficiency, Cost and Safety. Natural Working Fluids '98. IIR-Gustav Lorentzen Conference.
- Formats : PDF
Voir la fiche
-
An experimental study of ejectors supported by ...
- Auteurs : HAKKAKI-FARD A., POIRIER M., AIDOUN Z., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
A displacer type Stirling refrigerator of 100 w...
- Auteurs : SAKAMOTO M., YAMADA T., OTAKA T.
- Date : 02/06/1998
- Langues : Anglais
- Source : Natural Refrigerants, Energy Efficiency, Cost and Safety. Natural Working Fluids '98. IIR-Gustav Lorentzen Conference.
- Formats : PDF
Voir la fiche