Analyse d'un système de conditionnement d'air par accumulation d'énergie dans le sol associé à une déshumidification chimique.
Analysis of an air conditioning system using underground thermal energy storage combined with chemical dehumidification.
Auteurs : GASPARELLA A., MARRA R., LONGO G. A.
Résumé
In the paper, analysis of the performance of an underground thermal energy storage (UTES) system is compared with a traditional HVAC plant. In particular, the study aimed at evaluating the opportunities offered by the combination of the UTES with a desiccant-based air handling unit (AHU). Unlike in conventional solutions, the humidity control used here is separately obtained by chemical dehumidification of the ventilation airstream performed by liquid desiccants in a packed column. In winter, the AHU configuration allows sensible and latent heat recovery while in summer the borehole heat exchangers water temperature is generally suitable to meet the sensible load without any integration by the chillers. In this way not only operation but above all the investment costs are reduced and the UTES system competitiveness is increased. The described solutions are investigated by a computer simulation referring to a modern office building in northern Italy.
Documents disponibles
Format PDF
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Analysis of an air conditioning system using underground thermal energy storage combined with chemical dehumidification.
- Identifiant de la fiche : 2004-2443
- Langues : Anglais
- Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Date d'édition : 17/08/2003
Liens
Voir d'autres communications du même compte rendu (398)
Voir le compte rendu de la conférence
Indexation
-
Deshumidificación y humidificación: unidad dese...
- Auteurs : AYNUR T. N., HWANG Y., RADERMACHER R.
- Date : 04/2009
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 37 - n. 413
- Formats : PDF
Voir la fiche
-
A heat pump desiccant unit for dehumidification...
- Auteurs : AYNUR T. N., HWANG Y., RADERMACHER R.
- Date : 14/07/2008
- Langues : Anglais
- Source : 2008 Purdue Conferences. 19th International Compressor Engineering Conference at Purdue & 12th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Formats : PDF
Voir la fiche
-
Evaluating the ability of unitary equipment to ...
- Auteurs : BRANDEMUEHL M., KATEJANEKARN T.
- Date : 06/2001
- Langues : Anglais
Voir la fiche
-
Energy and Comfort Evaluation of Fresh Air-Base...
- Auteurs : NARAYANAN R., SETHUVENKATRAMAN S., PIPPIA R.
- Date : 10/2022
- Langues : Anglais
- Source : Energies - vol. 15 - n. 20
- Formats : PDF
Voir la fiche
-
Combination of ground source heat pumps with ch...
- Auteurs : GASPARELLA A., LONGO G. A., MARRA R.
- Date : 02/2005
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 25 - n. 2-3
Voir la fiche