ANALYSE DE L'ECOULEMENT LAMINAIRE ET DU TRANSFERT DE CHALEUR DANS LA REGION D'ENTREE D'UN CONDUIT CIRCULAIRE A AILETTES INTERNES.

ANALYSIS OF LAMINAR FLOW AND HEAT TRANSFER IN THE ENTRANCE REGION OF AN INTERNALLY FINNED CIRCULAR DUCT.

Auteurs : PRAKASH C., LIU Y. D.

Type d'article : Article

Résumé

ON A ANALYSE L'ECOULEMENT A CONVECTION FORCEE, LAMINAIRE, EN REGIME PERMANENT ET LE TRANSFERT DE CHALEUR DANS LA REGION D'ENTREE D'UN CONDUIT CIRCULAIREA AILETTES INTERNES. LES AILETTES SONT RADIALES ET CONTINUES. ON CONSIDERE DEUX TYPES DE CONDITIONS : UN APPORT DE CHALEUR UNIFORME PAR UNITE DE LONGUEUR AXIALE AVEC TEMPERATURE UNIFORME A LA PERIPHERIE POUR TOUTE SECTION TRANSVERSALE ETUNE TEMPERATURE UNIFORME AXIALEMENT ET A LA PERIPHERIE. LES RESULTATS MONTRENT LES GRADIENTS A HAUTE PRESSION ET LES COEFFICIENTS DE TRANSFERT DE CHALEUR ATTENDUS DANS LA REGION D'ENTREE. ON PRESENTE LES RESULTATS POUR 8, 16 ET 24 AILETTES ET POUR DES RAPPORTS DE LA HAUTEUR DES AILETTES AU RAYON DES CONDUITS DE 0,3, 0,6 ET 1. LE NOMBRE DE PRANDTL EST MAINTENU A 0,707, CE QUI CORRESPOND A L'AIR.

Détails

  • Titre original : ANALYSIS OF LAMINAR FLOW AND HEAT TRANSFER IN THE ENTRANCE REGION OF AN INTERNALLY FINNED CIRCULAR DUCT.
  • Identifiant de la fiche : 1986-0095
  • Langues : Anglais
  • Source : J. Heat Transf. - vol. 107 - n. 1
  • Date d'édition : 02/1985
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres articles du même numéro (6)
Voir la source