Document IIF
Analyse de l'impact des différentes conditions de fonctionnement sur les performances d'une pompe à chaleur réversible avec production d'eau chaude sanitaire.
Analysis of the impact of different operating conditions on the performance of a reversible heat pump with domestic hot water production.
Auteurs : JANKOVIC Z., SIERES J., CERDEIRA F., et al.
Type d'article : Article, Article de la RIF
Résumé
This paper presents the mathematical modeling of a liquid-to-water heat pump with scroll compressor, brazed plate heat exchangers, additionally built-in liquid-vapor heat exchanger (LVHX) and a desuperheater for domestic hot water (DHW) production. The refrigerant is the zeotropic mixture R407C and the liquid used in the outdoor loop is a propylene-glycol water mixture. Developed mathematical model is validated on experimental data and used as a tool for the heat pump analysis. Simulation results are obtained for the effect of the degree of superheat at the evaporator outlet, the subcooling degree at the condenser outlet, the effect of using or not the LVHX and the effect of using or not the desuperheater for DHW for typical operating conditions of liquid-to-water heat pumps (EN-14,511-2, 2011) in the cooling and heating modes (low and medium temperature applications). Results show that the effect of the degree of superheat or the decision on the suitability of using or not a LVHX may be different for heat pumps that include or not a desuperheater for DHW. In particular, if DHW is a priority, the use of a LVHX is recommended because it leads to higher COP (or EER) values as well as to higher DHW heating powers.
Documents disponibles
Format PDF
Pages : 282-291
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Analysis of the impact of different operating conditions on the performance of a reversible heat pump with domestic hot water production.
- Identifiant de la fiche : 30023149
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 86
- Date d'édition : 02/2018
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2017.11.005
Liens
Voir d'autres articles du même numéro (42)
Voir la source
Indexation
-
Screening of heat pump performance improvements...
- Auteurs : KOFLER R., ELMEGAARD B., MADSEN C., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Evaluation de l'efficacité d'un cycle de pompe ...
- Auteurs : SAIKAWA M., HASHIMOTO K.
- Date : 2001
- Langues : Japonais
- Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 18 - n. 3
Voir la fiche
-
Assessment of the influence of the intermediate...
- Auteurs : ILLÁN GÓMEZ F., GARCÍA-CASCALES J. R., SÁNCHEZ-VELASCO F. J., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Exergy analysis on a heat pump working between ...
- Auteurs : PITARCH M., HERVÁS-BLASCO E., NAVARRO-PERIS E., et al.
- Date : 03/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 99
- Formats : PDF
Voir la fiche
-
Investigation of heat pump seasonal efficiency ...
- Auteurs : WINANDY E., HUNDY G.
- Date : 29/03/2010
- Langues : Anglais
- Source : 1st IIR International Conference on Sustainability and the Cold Chain
- Formats : PDF
Voir la fiche