Recommandé par l'IIF
Analyse de l'inventaire énergétique des émissions de carbone provenant de la production de frigorigènes et de la compensation obtenue grâce à leur recyclage
Analysis of carbon emission energy inventory from refrigerant production and recycling carbon compensation
Résumé
At present, the massive emissions of carbon dioxide and nitrogen oxides and other greenhouse gases caused by human activities have caused more and more serious negative effects on global climate change. In order to cope with global warming and achieve sustainable development, achieve “carbon neutrality” as soon as possible. In the refrigeration industry, it is necessary to reduce greenhouse gas emissions related to refrigerants, including the production, use, and recycling of refrigerants. This paper has carried out the calculation of greenhouse gas emissions during the refrigerant preparation process, and compared and analyzed the emission reductions of refrigerant recycling and reuse; the research based on the energy consumption of the refrigerant production process uses the greenhouse gas emission inventory analysis method to Taking refrigerant R134a as an example, the carbon emission accounting boundary of the production process is set, the emission source is determined, the emission is calculated based on the emission factor method, and the emission inventory is established; the carbon offset effect of the recycling and reuse of the refrigerant is analyzed. The research results show that if the entire refrigerant industry fully recycles waste refrigerants, it can reduce carbon emissions by about 29.7% compared to just producing new refrigerants.
Documents disponibles
Format PDF
Pages : 13
Disponible
Gratuit
Détails
- Titre original : Analysis of carbon emission energy inventory from refrigerant production and recycling carbon compensation
- Identifiant de la fiche : 30029227
- Langues : Anglais
- Sujet : Environnement
- Source : Applied Sciences - vol. 12 - n. 1
- Éditeurs : MDPI
- Date d'édition : 01/2022
- DOI : http://dx.doi.org/10.3390/app12010001
Liens
Voir la source
Indexation
-
Supermarket refrigeration system charge reducti...
- Auteurs : SHARMA V., FRICKE B., BANSAL P.
- Date : 02/08/2014
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
Voir la fiche
-
Handling and reuse of refrigerants in the Unite...
- Date : 06/1994
- Langues : Anglais
- Source : ARI, Ind. Recycl. Guidel. - IRG-1; 10 p.; 1 fig.; 1 tabl.
Voir la fiche
-
Final rule summary: complying with the section ...
- Date : 08/1995
- Langues : Anglais
- Source : EPA, Off. Air Radiat., Fact Sheet - n. 1
Voir la fiche
-
Experimental evaluation of R513A as a low GWP r...
- Auteurs : BELMAN-FLORES J. M., HEREDIA-ARICAPA Y., PARDO-CELY D. M., RODRIGUEZ-VALDERRAMA D. A., DE ALBA-ROSANO M., SILVA-ROMERO J. C.
- Date : 10/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 142
- Formats : PDF
Voir la fiche
-
The refrigerant recovery book.
- Auteurs : CLODIC D., SAUER F.
- Date : 1994
- Langues : Anglais
Voir la fiche