Document IIF
Analyse de la performance d’un éjecteur sous différentes conditions de fonctionnement, prenant en considération la structure de tuyère ajustable.
Ejector performance analysis under overall operating conditions considering adjustable nozzle structure.
Résumé
The variable-geometry ejector (VGE) is feasible for unstable heat-source utilization; the ejector can be adjusted to its design point to obtain high efficiency. Moreover, as the adjustable nozzle in the VGE significantly affects the performance of the ejector, a theoretical model is necessary to evaluate VGE performance. In this study, a two-dimensional theoretical model was proposed based on an adjustable-nozzle theory. Method of characteristics was employed to accurately predict the driving-flow development in the mixing section. In addition, the suction-flow velocity distribution on the effective area was considered. The proposed model was validated by employing the data from literature and additional experimental data obtained from a VGE test setup using R134a. The validation result shows that the proposed model predicts the ejector performance accurately; moreover, the model is more adaptive while the nozzle configuration changes. The theoretical model, proposed herein, is practical for the design and application of the VGE.
Documents disponibles
Format PDF
Pages : 274-286
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Ejector performance analysis under overall operating conditions considering adjustable nozzle structure.
- Identifiant de la fiche : 30022538
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 84
- Date d'édition : 12/2017
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2017.08.005
Liens
Voir d'autres articles du même numéro (26)
Voir la source
Indexation
- Thèmes : Systèmes à éjection, cycle à air, cycle Stirling, autres cycles
- Mots-clés : Vitesse (fluides); R134a; Tuyère; Rendement; Performance; Modélisation; Éjecteur
-
Simulation study of key cross-sectional area di...
- Auteurs : ZENG H., ZHAO H., ZHANG H., LIU Z.
- Date : 03/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 159
- Formats : PDF
Voir la fiche
-
Influence of ejector performance on the overall...
- Auteurs : BANASIAK K., HAFNER A.
- Date : 09/05/2013
- Langues : Anglais
- Source : 5th Conference on Ammonia Refrigeration Technology. Proceedings: Ohrid, North Macedonia, May 9-11, 2013.
- Formats : PDF
Voir la fiche
-
1D analysis of CO2 sub-cooled/supercritical eje...
- Auteurs : KSAYER E. B. L., CLODIC D.
- Date : 07/09/2008
- Langues : Anglais
- Source : 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Formats : PDF
Voir la fiche
-
Optimal nozzle exit position for an ejector ref...
- Auteurs : RAND C. P., CROQUER S., POIRIER M., PONCET S.
- Date : 11/04/2022
- Langues : Anglais
- Source : 7th IIR International Conference on Sustainability and the Cold Chain (Online). Proceedings: April 11-13 2022
- Formats : PDF
Voir la fiche
-
Investigation on a novel ejector – based regene...
- Auteurs : REN J., LADD D., ZIVIANI D., GROLL E. A.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche