Analyse de performance d'un cycle de turbine à gaz avec injection de vapeur d'oxydation partielle.
Performance analysis of a partial oxidation steam injected gas turbine cycle.
Auteurs : ZHANG S. J., CHI J. L., XIAO Y. H.
Type d'article : Article
Résumé
Partial oxidation gas turbine (POGT) has great potential in improving efficiency because of staged releasing of the chemical energy of fuel. Several researchers have studied the applications of POGT in repowering of different existing power plants. In this study, the POGT is integrated with a steam injected gas turbine (STIG) cycle. This research evaluated the overall thermodynamic performance of a partial oxidation steam injected gas turbine (POSTIG) cycle and investigated the influences of key variables. In addition, comparisons with the STIG cycle were conducted based on exergy analysis. Results show that the combustor outlet temperature of the bottoming gas turbine cycle, the pressure ratio of the bottoming gas turbine cycle compressor, and the temperature of partial oxidation affected the efficiency and specific work output of the POSTIG cycle obviously. Compared with the simple gas turbine cycle, the oxygen concentration in the combustor outlet gas of the POSTIG cycle decreases significantly, and the cooling flow rate increases. Efficiency of the POSTIG cycle is at least two percentage points higher than that of the STIG cycle because of the production and utilization of higher quality steam, along with lower exergy destruction during the graded release of the fuel's chemical energy.
Détails
- Titre original : Performance analysis of a partial oxidation steam injected gas turbine cycle.
- Identifiant de la fiche : 30017169
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 91
- Date d'édition : 05/12/2015
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2015.08.062
Liens
Voir d'autres articles du même numéro (57)
Voir la source
Indexation
- Thèmes : Systèmes à compression
- Mots-clés : Oxydation; Exergie; Vapeur; Turbine a gaz; Refroidissement; Performance
-
VAPOUR RECOMPRESSION BY EJECTORS.
- Auteurs : KREJ-CI S.
- Date : 1985
- Langues : Anglais
- Source : J. Heat Recov. Syst. - vol. 5 - n. 5
Voir la fiche
-
Exergy analysis of R1234yf and R1234ze as R134a...
- Auteurs : YATAGANBABA A., KILICARSLAN A., KURTBAS I.
- Date : 12/2015
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 60
- Formats : PDF
Voir la fiche
-
Alternatives à l'utilisation des groupes frigor...
- Auteurs : SAULNIER B.
- Date : 07/1993
- Langues : Français
- Source : Rev. gén. Froid - vol. 83 - n. 935
Voir la fiche
-
ANALYSE EXERGETIQUE DE L'INFLUENCE DE LA REGENE...
- Auteurs : HAN B. G.
- Date : 03/1983
- Langues : Chinois
- Source : J. chin. Assoc. Refrig. - n. 1
Voir la fiche
-
Mechanical sub-cooling vapor compression system...
- Auteurs : QURESHI B. A., ZUBAIR S. M.
- Date : 12/2013
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 8
- Formats : PDF
Voir la fiche