ANALYSE DES MESURES DE LA PRESSION ET DE LA TEMPERATURE LE LONG D'UN ECHANGEUR DE CHALEUR CONSTITUE PAR LE TUBE CAPILLAIRE ET LA CONDUITE D'ASPIRATION.

AN ANALYSIS OF PRESSURE AND TEMPERATURE MEASUREMENTS ALONG A CAPILLARY TUBE-SUCTION LINE HEAT EXCHANGER.

Auteurs : PATE M. B., TREE D. R.

Résumé

ON A MESURE SPECIFIQUEMENT LES PRESSIONS DANS LE TUBE CAPILLAIRE, LES TEMPERATURES DE LA PAROI DES TUBES ET LES TEMPERATURES DU FLUIDE DE LA CONDUITE D'ASPIRATION A DES INTERVALLES DE 0,30 METRE DANS DES CONDITIONS SEMBLABLES A CELLES D'UN SYSTEME FRIGORIFIQUE A R12 EN FONCTIONNEMENT REEL. LES RESULTATS ONT MONTRE QUE LE COMPORTEMENT D'UN TUBE CAPILLAIRE AVEC TRANSFERT DE CHALEUR EST CONSIDERABLEMENT DIFFERENT DE CELUI D'UN TUBE CAPILLAIRE ADIABATIQUE. LE TRANSFERT DE CHALEUR AUGMENTE LA LONGUEUR DE LA REGION DIPHASIQUE TOUT EN REDUISANT LA RESTRICTION D'ECOULEMENT.

Détails

  • Titre original : AN ANALYSIS OF PRESSURE AND TEMPERATURE MEASUREMENTS ALONG A CAPILLARY TUBE-SUCTION LINE HEAT EXCHANGER.
  • Identifiant de la fiche : 1986-0152
  • Langues : Anglais
  • Date d'édition : 1984
  • Source : Source : ASHRAE Trans.
    vol. 90; n. 2A; 291-301; 11 fig.; 4 ref.
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.