Recommandé par l'IIF / Document IIF

Analyse du froid hybride à absorption-compression utilisant des couples de travail HFC ou HFO/liquide ionique à faible PRP.

Analysis of hybrid compression absorption refrigeration using low-GWP HFC or HFO/ionic liquid working pairs.

Auteurs : ASENSIO-DELGADO J. M., ASENSIO-DELGADO S., ZARCA G., URTIAGA A.

Type d'article : Article de la RIF

Résumé

Absorption refrigeration systems (ARS) are the leading alternative for reducing the electricity costs associated with compression refrigeration systems. However, classical pairs based on NH3/H2O and H2O/LiBr have drawbacks that limit their practical application. In this work, we analyze 16 pairs of refrigerant gases and ionic liquid sorbents based on two low global warming potential (GWP) hydrofluorocarbons (HFCs), R32 and R134a, and two novel hydrofluoroolefins (HFOs), R1234ze(E) and R1234yf, using the low-viscosity ionic liquids [C2mim][BF4], [C2mim][OTf], [C2mim][SCN], and [C2mim][Tf2N]. We provide new data and modeling of the vapor-liquid equilibria of R1234ze(E) with [C2mim][OTf], [C2mim][SCN] and [C2mim][Tf2N]. ARS performance in single-effect (SE-ARS) and compression-assisted absorption refrigeration (CA-ARS), in terms of coefficient of performance (, ), solution circulation factor (), and the thermal and electrical contribution to the total , is evaluated through energy and exergy analyses. The results showed that CA-ARS performs better even at lower generator temperatures. In addition, HFCs returned a better performance than HFOs because of their higher solubility in ILs. The working pair R32/[C2mim][Tf2N] gave the best results,  = 0.74 and  = 5.4 at 328 K in the desorber, and a maximum of 0.41 at 318 K. Furthermore, the HFO R1234ze(E), with a lower working pressure and negligible GWP, is also a promising option for CA-ARS. In conclusion, we consider that ARS with the HFC or HFO/IL pairs examined in this study shows outstanding potential as a more energy efficient system compared to compression systems, when an inexpensive energy source is available.

Documents disponibles

Format PDF

Pages : 232-241

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Analysis of hybrid compression absorption refrigeration using low-GWP HFC or HFO/ionic liquid working pairs.
  • Identifiant de la fiche : 30029350
  • Langues : Anglais
  • Sujet : Technologie
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 134
  • Date d'édition : 02/2022
  • DOI : http://dx.doi.org/10.1016/j.ijrefrig.2021.11.013
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres articles du même numéro (29)
Voir la source