Document IIF
Analyse énergétique et exergétique d'un système de conditionnement d'air expérimental à absorption au NH3-LiNO3.
Energy and exergy analysis of an experimental NH3-LiNO3 air-conditioning absorption system.
Auteurs : COLORADO D., RIVERA W., CONDE-GUTIÉRREZ R. A., JIMÉNEZ-GARCÍA J. C.
Type d'article : Article de la RIF
Résumé
An energy and exergy analysis of an experimental air-conditioning absorption system operating with the ammonia-lithium nitrate mixture has been performed. The system was operated under controlled and steady-state conditions. The main operating parameters, such as flow ratio, coefficient of performance, exergy coefficient of performance, and exergy destruction in each one of the main components, were determined at different heat sources and condensing temperatures. The coefficients of performance varied between 0.5 and 0.65, while the exergy coefficients of performance varied between 0.1 and 0.2. Clear trends were found for the coefficient of performance and flow ratio as a function of the generator and condenser temperatures; however, no trends were found in the exergy coefficients of performance due to the high variability of the ambient temperature. The highest values of the exergy destruction occurred in the generator, followed by the condenser and the evaporator, while the lowest values were obtained in the absorber and the economizer.
Documents disponibles
Format PDF
Pages : 393-405
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Energy and exergy analysis of an experimental NH3-LiNO3 air-conditioning absorption system.
- Identifiant de la fiche : 30032483
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 165
- Date d'édition : 09/2024
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2024.05.031
Liens
Voir d'autres articles du même numéro (39)
Voir la source
Indexation
-
Energy and exergy analysis of single effect and...
- Auteurs : KAUSHIK S. C., ARORA A.
- Date : 09/2009
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 6
- Formats : PDF
Voir la fiche
-
ETUDE DES SYSTEMES FRIGORIFIQUES A ABSORPTION.
- Auteurs : YAMASAKI H., SAKO M., CHIBA T.
- Date : 1985
- Langues : Japonais
- Source : Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 28
Voir la fiche
-
Thermodynamic modelling of a two-stage absorpti...
- Auteurs : FIGUEREDO G. R., BOUROUIS M., CORONAS A.
- Date : 02/2008
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 28 - n. 2-3
Voir la fiche
-
On the efficiencies of absorption heat transfor...
- Auteurs : JERNQVIST A., ABRAHAMSSON K., ALY G.
- Date : 07/1992
- Langues : Anglais
- Source : Heat Recov. Syst. CHP - vol. 12 - n. 4
Voir la fiche
-
A HIGH EFFICIENCY AMMONIA-WATER ABSORPTION POWE...
- Auteurs : ROGDAKIS E. D., ANTONOPOULOS K. A.
- Date : 1991
- Langues : Anglais
- Source : Heat Recov. Syst. CHP - vol. 11 - n. 4
Voir la fiche