Document IIF

Analyse exergétique et économique d'un système de tunnel souterrain utilisé pour refroidir des serres.

Exergoeconomic analysis of an underground air tunnel system for greenhouse cooling system.

Auteurs : OZGENER O., OZGENER L.

Type d'article : Article, Article de la RIF

Résumé

This paper investigates some exergoeconomic parameters for an underground air tunnel system based upon some operating conditions. The ratio of exergy loss rate to capital cost changes between 0.052 and 0.552. The total exergy losses values are obtained to be from 0.26 to 2.50 kW for the system. The daily average maximum cooling COP values for the system are also obtained to be 11.96 for experimental period, while the total average COP is found to be 5.89. The overall exergy efficiency value for the system on a product/fuel basis is found to be 56.9%.

Documents disponibles

Format PDF

Pages : pp. 995-1005

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Exergoeconomic analysis of an underground air tunnel system for greenhouse cooling system.
  • Identifiant de la fiche : 2010-0923
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 33 - n. 5
  • Date d'édition : 08/2010

Liens


Voir d'autres articles du même numéro (14)
Voir la source