Document IIF
Analyse exergétique et énergétique du R513a comme frigorigène de remplacement immédiat du R134a dans un système frigorifique à compression de vapeur.
Energy and exergy analyses of R513a as a R134a drop-in replacement in a vapor compression refrigeration system.
Résumé
R513a (XP10), a mixer of 56% R1234yf (C3H2F4) and 44% R134a (CH2FCF3), has similar thermophysical characteristics to R134a but only half of its global warming potential (GWP). This paper uses an economized-cycle vaper compression refrigeration system as an example to investigate the energy and exergy performance of R513a used as a drop-in replacement for R134a. Differing from previous research, this study examines the entire system operating zone to identify the performance differences in terms of capacity, COP, exergy destruction rate, and exergy efficiency between R513a and R134a systems. The analysis found that a system with drop-in R513a demonstrates reduced capacity by up to 12% and efficiency (up to 9% with COP and 14% with exergy efficiency) under a majority of operating conditions, while exhibiting less irreversibility (5% to 13%) under high-ambient, high-space temperature conditions and better exergy efficiency of 3% in low-ambient conditions. In addition, the contribution of each individual component to the exergy destruction rate at various operating conditions is identified. To improve the energy and exergy efficiency of a R513a system, the analysis results indicate that the compressor is the first component that should be redesigned or reselected, followed by the economizer, valves, and evaporator. The condenser influence is negligible.
Documents disponibles
Format PDF
Pages : 348-356
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Energy and exergy analyses of R513a as a R134a drop-in replacement in a vapor compression refrigeration system.
- Identifiant de la fiche : 30027408
- Langues : Anglais
- Sujet : Alternatives aux HFC
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 112
- Date d'édition : 04/2020
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2019.12.014
Liens
Voir d'autres articles du même numéro (30)
Voir la source
Indexation
-
Thèmes :
HFC;
Systèmes à compression - Mots-clés : R134a; R513A; Remplacement immediat; Système à compression; Substitut; Exergie; COP; Modélisation
-
Drop-in analysis of R450A and R513A as low-GWP ...
- Auteurs : MOLINAROLI L., LUCCHINI A., COLOMBO L. P. M.
- Date : 03/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 135
- Formats : PDF
Voir la fiche
-
Drop-in energy performance evaluation of R1234y...
- Auteurs : MOTA BABILONI A., NAVARRO-ESBRÍ J., BARRAGÁN A., et al.
- Date : 10/2014
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 71 - n. 1
Voir la fiche
-
Liquid-to-suction heat exchanger assessment usi...
- Auteurs : MOTA BABILONI A., NAVARRO-ESBRÍ J., MATEU-ROYO C., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Energy evaluation of drop-in replacements for R...
- Auteurs : MAKHNATCH P., MOTA BABILONI A., KHODABANDEH R.
- Date : 18/06/2018
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
Voir la fiche
-
Experimental analysis of R-450A and R-513A as r...
- Auteurs : LLOPIS R., SÁNCHEZ D., CABELLO R., et al.
- Date : 12/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 84
- Formats : PDF
Voir la fiche