Document IIF

Analyse expérimentale d'un régénérateur magnétique actif faisant appel à deux matériaux.

Experimental analysis of a two-material active magnetic regenerator.

Auteurs : ARNOLD D. S., TURA A., ROWE A.

Type d'article : Article, Article de la RIF

Résumé

Experimental results of an active magnetic regenerator (AMR) composed of two equal volumes of gadolinium and Gd(0.85)Er(0.15) using 2 and 5 T are reported. Drive forces and system losses are measured as a function of thermal load and magnetic field. Metrics for coefficient of performance and efficiency are defined and used to distinguish between regenerator and device performance. Results suggest the largest temperature spans are expected to occur when each material is operating with its average temperature near their Curie temperatures. Force measurements indicate that mechanical losses and pumping power are the most significant contributions to network while the net magnetic work is too small to be resolved. COP values for the magnetic cycle are as high as 2.4 while efficiencies are all less than 0.15. A maximum exergetic cooling of 1.94 W is estimated with a corresponding specific exergetic cooling power of 23 W/T.L.

Documents disponibles

Format PDF

Pages : pp. 178-191

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental analysis of a two-material active magnetic regenerator.
  • Identifiant de la fiche : 2010-1464
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 1
  • Date d'édition : 01/2011

Liens


Voir d'autres articles du même numéro (36)
Voir la source