Analyse numérique couplée de la température des écrans, des pertes thermiques et des pressions du gaz résiduel dans un superisolant sous vide, combinant réseaux thermiques et réseaux de fluides. II. Régime transitoire (période de refroidissement).

A coupled numerical analysis of shield temperatures, heat losses and residual gas pressures in an evacuated super-insulation using thermal and fluid networks. II. Unsteady-state conditions (cool-down period).

Auteurs : REISS H.

Type d'article : Article

Résumé

This paper analyses the cool-down period of a 300 L super-insulated cryogenic storage tank for liquid nitrogen. Storage tank and evacuated shields are the same as described in part I of this paper (see the Bulletin of the IIR, reference 2005-1097) where stationary states were investigated. The aim of this paper is to introduce thermal resistance networks as a tool to quantitatively understand and control also unsteady-states like cool-down of super-insulations. Numerical simulations using thermal resistance networks have been performed to determine time dependence of local shield temperatures and heat loss components. Coupling between radiation and solid conduction is investigated under these conditions. Using the numerical results, the author has checked an experimental method suggested in the literature to separate heat losses through the insulation from losses through thermal bridges by measurement of unsteady-state evaporation rates. The results of the simulations confirm that it takes the outer shields much longer to reach stationary temperature; cool-down does not proceed uniformly in the super-insulation. Coupling between different heat transfer modes again is obvious. Thermal emissivity is important also during the early phase of cool-down. Using the obtained numerical results, the experimental method to separate heat loss components could only roughly been confirmed for thick metallic foils. [Reprinted with permission from Elsevier. Copyright, 2006]. See also this Bulletin, reference 2007-0012.

Détails

  • Titre original : A coupled numerical analysis of shield temperatures, heat losses and residual gas pressures in an evacuated super-insulation using thermal and fluid networks. II. Unsteady-state conditions (cool-down period).
  • Identifiant de la fiche : 2007-0011
  • Langues : Anglais
  • Source : Cryogenics - vol. 46 - n. 12
  • Date d'édition : 12/2006

Liens


Voir d'autres articles du même numéro (4)
Voir la source