Document IIF

Analyse par simulation CFD et étude expérimentale par visualisation de la distribution de la condensation lors de la contamination du gaz dans un cryorefroidisseur à tube à pulsation coaxial.

CFD simulation analysis and visualization experimental study of gas contamination condensation distribution in coaxial pulse tube cryocooler.

Auteurs : MA J., SHAO B., ZHAO P., JIANG Z., LIU S., DONG D.

Type d'article : Article de la RIF

Résumé

Condensable gas contamination is one of important factors limiting the longevity of pulse tube coolers. To further understand the way in which contamination affect the performance of pulse tube cooler, the behavioral characteristics of the contamination inside the pulse tube cooler were investigated. In this study, a 2-D simulation model of the regenerator was developed, and the diffusion and phase change distribution characteristics of the contamination at the cold end were investigated by CFD method. The transition of gas flow and pressure loss caused by the contamination were analyzed. The results show that condensation occurs first in the pulse tube and distribute mainly in the pulse tube and the regenerator eventually. The transition of the gas flow state due to the accumulation of contamination is likely to be an important cause of degradation in the performance of pulse tube
cooler. And contamination will accumulate in the flow straightener when the cooling temperature closer to the saturation temperature, which can further affect the state of gas flow in the pulse tube, resulting in higher pressure losses. In addition, based on the technology of neutron radiography, a visualization experiment on the accumulation of contamination in pulse tube cooler was completed, and the experimental results were compared with the simulation results.

Documents disponibles

Format PDF

Pages : 10 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : CFD simulation analysis and visualization experimental study of gas contamination condensation distribution in coaxial pulse tube cryocooler.
  • Identifiant de la fiche : 30034218
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 174
  • Date d'édition : 06/2025
  • DOI : http://dx.doi.org/10.1016/j.ijrefrig.2025.03.016

Liens


Voir d'autres articles du même numéro (28)
Voir la source

Indexation

  • Thèmes : N/A
  • Mots-clés : N/A