Document IIF
Analyse pinch de l'échange thermique dans une unité de séparation d'air utilisant l'énergie cryogénique du gaz naturel liquéfié (GNL).
Pinch point analysis of heat exchange for liquid nature gas (LNG) cryogenic energy using in air separation unit.
Résumé
Due to strong nonlinear variation of supercritical liquid nature gas (LNG) and nitrogen (N2) isobaric heat capacity with temperature and pressure, pinch point analysis is conducted for heat exchange process between LNG and N2 and its effect on the air separation unit cooled by LNG cryogenic energy (CEASU) is studied in the present study. The effect of pinch point value, temperature difference at the cold end and pressure of N2 on mass flow ratio (N2 to LNG), approach temperature difference, energy consumption of CEASU and cryogenic energy utilization rate are analyzed in detail. For the heat exchanger process between LNG and N2, the different value of pinch point have little effect on its location, and increasing the temperature difference at the cold end effectively increases the mass flow ratio and decreases the approach temperature difference, while rising the pressure of N2 leads to a valley value of the mass flow ratio, in contrast to a peak value in the approach temperature difference. For the energy consumption of CEASU, choosing the lower temperature difference at the cold end is good for the energy consumption and equivalent energy consumption per kilogram liquid production, but a large amount of LNG is needed and cryogenic energy could not be fully used; while the influence of pressure of N2 on the energy consumption presents different variation trend. The result shows the energy consumption per kilogram liquid production of proposed CEASU is roughly 5–12% lower than that of convectional processes which the cryogenic energy is only used for cooling the nitrogen or the feed air.
Documents disponibles
Format PDF
Pages : 264-276
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Pinch point analysis of heat exchange for liquid nature gas (LNG) cryogenic energy using in air separation unit.
- Identifiant de la fiche : 30024075
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 90
- Date d'édition : 06/2018
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2017.12.015
Liens
Voir d'autres articles du même numéro (24)
Voir la source
Indexation
-
Thèmes :
Liquéfaction et séparation des gaz;
GNL et GPL - Mots-clés : Capacité thermique; Air; Simulation; Séparation; GNL; Cryogénie; Échangeur de chaleur
-
Design and analysis of CO2 cryogenic...
- Auteurs : BI Y., JU Y.
- Date : 10/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 130
- Formats : PDF
Voir la fiche
-
Enhance gas processing with reflux heat exchang...
- Auteurs : FINN A. J., SAMDANI G.
- Date : 1994
- Langues : Anglais
- Source : Ger. chem. Eng. - vol. 101 - n. 5
Voir la fiche
-
Exergy analysis of an LNG BOG re-liquefaction p...
- Auteurs : BELADJINE M. B., OUADHA A., BENABDESSELAM Y., et al.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
Utilization of cold energy of liquefied natural...
- Auteurs : JOY J., SINGLA R., CHOWDHURY K.
- Date : 08/05/2019
- Langues : Anglais
- Source : Cryogenics 2019. Proceedings of the 15th IIR International Conference: Prague, Czech Republic, April 8-11, 2019.
- Formats : PDF
Voir la fiche
-
Utilization of engine exhaust gas in boil-off g...
- Auteurs : KOCHUNNI S. K., CHOWDHURY K.
- Date : 08/05/2019
- Langues : Anglais
- Source : Cryogenics 2019. Proceedings of the 15th IIR International Conference: Prague, Czech Republic, April 8-11, 2019.
- Formats : PDF
Voir la fiche