Résumé

A G-M/J-T helium refrigerator system is designed for a cryoadsorption test facility at 4.5K. The refrigerator includes a heat exchanger consisted by counterflow of J-T valve and a helically twined single finned-tube. A nonlinear variable specific heat capacity model for helium gas under 15K has been developed by the law of thermodynamics to study the thermal characteristics of the heat exchanger. Its performance is discussed for the test works in various operation conditions and the results indicate that weakening the interact surrounding environment and enhancing the number of Cr are practical and reasonable for the heat exchanger and useful for performance analysis of similar heat exchangers.

Documents disponibles

Format PDF

Pages : 6

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Thermodynamic analysis of a J-T heat exchanger used in G-M/J-T helium refrigerator for a cryoadsorption test facility.
  • Identifiant de la fiche : 30018367
  • Langues : Anglais
  • Source : 1st IIR International Conference of Cryogenics and Refrigeration Technology (ICCRT 2016). Proceedings: Bucharest, Romania, June 22-25, 2016.
  • Date d'édition : 22/06/2016
  • DOI : http://dx.doi.org/10.18462/IIR.ICCRT.2016.0032

Liens


Voir d'autres communications du même compte rendu (32)
Voir le compte rendu de la conférence