Analyse thermodynamique de la courbure optimale pour une convection laminaire forcée pleinement développée dans un tube hélicoïdal au flux thermique uniforme.

Thermodynamic analysis of optimal curvature ratio for fully developed laminar forced convection in a helical coiled tube with uniform heat flux.

Auteurs : KO T. H.

Type d'article : Article

Résumé

In the paper, the optimal curvature ratio for steady, laminar, fully developed forced convection in a helical coiled tube with constant wall heat flux was analyzed by thermodynamic second law based on minimal entropy generation principle. Two working fluids, including air and water, are considered.

Détails

  • Titre original : Thermodynamic analysis of optimal curvature ratio for fully developed laminar forced convection in a helical coiled tube with uniform heat flux.
  • Identifiant de la fiche : 2006-2256
  • Langues : Anglais
  • Source : International Journal of thermal Sciences - vol. 45 - n. 7
  • Date d'édition : 07/2006

Liens


Voir d'autres articles du même numéro (2)
Voir la source