Document IIF

Analyses théoriques préliminaires de la performance thermique et la consommation d'énergie disponible d'un chauffe-eau à pompe à chaleur à cycle en cascade bi-étagé.

Preliminary theoretical analyses of thermal performance and available energy consumption of two-stage cascade cycle heat pump water heater.

Auteurs : WANG G., CHEN Z., LI C., et al.

Type d'article : Article, Article de la RIF

Résumé

In this paper, the analysis model of thermal performance and available energy of two-stage cascade cycle heat pump water heater (HPWH) was established. For the first time, the equivalent transformation thermodynamic analysis method and available energy consumption equation were employed to carry out the theoretical analyses of thermal performance and available energy consumption for two-stage cascade cycle HPWH. And the correctness of the analysis approach proposed in this paper was verified by an example. The calculation results showed a significant agreement with the results derived by the first law of thermodynamics and energy conservation law. The available energy analysis of two-stage cascade cycle HPWH clearly revealed the available energy consumption rates for different working processes, including heat transfers of heat exchangers, flow of heat-carrying fluid, working medium cycle, output of hot water, etc. This approach could be conveniently used in the analyses of thermal performance and available energy consumption for actual complex thermal system with irreversible process. This paper provided the theoretical basis for the actual optimization design and operation analysis of cascade type heat pump systems, and furthermore, the results of the calculation instance would also have a certain reference value.

Documents disponibles

Format PDF

Pages : 381-388

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Preliminary theoretical analyses of thermal performance and available energy consumption of two-stage cascade cycle heat pump water heater.
  • Identifiant de la fiche : 30022317
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 82
  • Date d'édition : 10/2017
  • DOI : http://dx.doi.org/10.1016/j.ijrefrig.2017.06.016

Liens


Voir d'autres articles du même numéro (42)
Voir la source