Résumé
Untreated urban sewage contains large amounts of thermal energy; and its temperature is suitable as a heat source in heat pumps for the heating and cooling of buildings. However, it is not widely used in heat pump systems due to the problem of filth. This paper presents an untreated sewage source heat pump (USSHP) system in which auto-avoiding-clogging equipment is used to continuously capture suspended solids in the sewage. Thus, the block problems caused by filtration and fouling in the heat exchanger tubes can be efficiently resolved in this system. In an actual engineering application, the characteristic parameters of USSHP system are tested under typical operating conditions for heating status. Based on the test results, the performances of the USSHP system are examined. The results indicate that the thermal resistance of the convective heat transfer and fouling on the sewage side in the sewage exchanger is 80% of its total thermal resistance. The COP of the heat pump unit and the COP of the USSHP system are 4.3 and 3.6, respectively.
Détails
- Titre original : Application of a heat pump system using untreated urban sewage as a heat source.
- Identifiant de la fiche : 30010284
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 62 - n. 2
- Date d'édition : 01/2014
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2013.08.028
Liens
Voir d'autres articles du même numéro (15)
Voir la source
Indexation
- Thèmes : Techniques des pompes à chaleur
- Mots-clés : Refroidissement; Source de chaleur; Pompe à chaleur; Performance; Essai; Chauffage; Eau usée
-
SEWAGE-SOURCE HEAT PUMPS IN COLD REGIONS.
- Auteurs : PHETTEPLACE G. E., UEDA H. T.
- Date : 03/1991
- Langues : Anglais
- Source : IEA HPC Newsl. - vol. 9 - n. 1
Voir la fiche
-
Analyse de la performance des conditions de cha...
- Auteurs : WANG X., ZHAO L., LI Y.
- Date : 01/2008
- Langues : Chinois
- Source : HV & AC - vol. 38 - n. 207
- Formats : PDF
Voir la fiche
-
EAUX USEES NON TRAITEES COMME SOURCE DE CHALEUR...
- Auteurs : HYDEN H., ERICSSON B., ZETTERLING H.
- Date : 1985
- Langues : Suédois
- Source : Swed. Counc. Build. Res. - R99:1985; 125 p.; fig.
Voir la fiche
-
LES EFFLUENTS, SOURCES DE CHALEUR POUR UNE POMP...
- Auteurs : HALLENBERG J., WAHLBERG H.
- Date : 1982
- Langues : Suédois
- Source : Swed. Counc. Build. Res. - R125:1982; 28 p.
Voir la fiche
-
EXPERIENCES WITH A 3.3 MW HEAT PUMP USING SEWAG...
- Auteurs : LINDSTROM H. O.
- Date : 1985
- Langues : Anglais
- Source : J. Heat Recov. Syst. - vol. 5 - n. 1
Voir la fiche