Besoin en énergie des réfrigérateurs liés aux conditions d'ouverture des portes.

Energy requirements of refrigerators due to door opening conditions.

Auteurs : TERRELL W. Jr

Résumé

The goal of this study was to predict the heat and mass transfer effects due to a refrigerator door being opened or a container being placed back into the refrigerator. An experimental investigation was conducted with separate testing in open cavities and simulated containers. The cavities and objects were heated to initial plate temperatures before being exposed to the ambient air. From the change in plate temperatures, the overall heat transfer coefficient was determined. The heat/mass transfer analogy was utilized to compute the mass transfer to the open cavities and objects. The sensible and latent energy loading due to door opening conditions was compared to other contributors to the refrigerator cabinet loading.

Documents disponibles

Format PDF

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Energy requirements of refrigerators due to door opening conditions.
  • Identifiant de la fiche : 2007-1615
  • Langues : Anglais
  • Source : 2006 Purdue Conferences. 18th International Compressor Engineering Conference at Purdue & 11th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
  • Date d'édition : 17/07/2006

Liens


Voir d'autres communications du même compte rendu (157)
Voir le compte rendu de la conférence