Document IIF
Calcul de l'HSPF (facteur de performance saisonnière en mode chauffage) d'un système à compression biétagé permettant de basculer sur un système à compression monoétagé.
HSPF calculation of an economizer two-stage compression system allowing switching to one-stage compression system.
Auteurs : BARBOUCHI S., RITZ J. B., CLODIC D.
Résumé
In France, 62% of heating installations in existing residential buildings are hydronic systems. It is often the case that a high supply temperature of about 65°C is required during the coldest days in order to ensure comfort. For this a two-stage compression heat pump is an adequate way in which high temperature can be reached by low outdoor air temperature. Nevertheless, when the weather becomes warmer, a single-stage compression system is more efficient than a two-stage system. Thus, to optimize the HSPF (heating seasonal performance factor), a system allowing switching from a single-stage compression system to a two-stage one has been studied. The study aims at evaluating the gain of switching from a single-stage to a two-stage compression system and to calculate a HSPF in accordance with the house type and the heat network. The input power and the heating capacity of the heat pump have been expressed in relation to the outdoor air temperature and the inlet water temperature of the condenser in single-stage and in two-stage modes. The system includes the house, the radiators, and the hydronic circuit. Models depicting each component of the heating system have been coded in a numerical tool to simulate the behaviour of the system in a quasi-static state, and then to evaluate the COP for the heating season.
Documents disponibles
Format PDF
Pages : ICR07-E2-1456
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : HSPF calculation of an economizer two-stage compression system allowing switching to one-stage compression system.
- Identifiant de la fiche : 2008-0864
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Date d'édition : 21/08/2007
Liens
Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence
Indexation
-
HSPF calculation of a system allowing switching...
- Auteurs : BARBOUCHI S., RITZ J. B., CLODIC D.
- Date : 17/07/2006
- Langues : Anglais
- Source : 2006 Purdue Conferences. 18th International Compressor Engineering Conference at Purdue & 11th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Formats : PDF
Voir la fiche
-
Aspects regarding the energy efficiency increas...
- Auteurs : HERA D., ILIE A., DUMITRESCU R.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Two-stage air-source heat pump for residential ...
- Auteurs : BERTSCH S. S., GROLL E. A.
- Date : 11/2008
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 7
- Formats : PDF
Voir la fiche
-
How small could a "small" heat pump be? The rel...
- Auteurs : PAUL J., RIISAGER C., ARNARSON S. A.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Polivalentne toplotne pumpe sa zemljom kao topl...
- Auteurs : ALBIERI M., LENA S., MASOCH A.
- Date : 03/12/2008
- Langues : Serbe
- Source : Zbornik radova. 39. Medunarodni kongres o grejanju, hladenju i klimatizaciji.
- Formats : PDF
Voir la fiche