Résumé
This study experimentally investigates a rotary compressor (Hitachi Highly BSA645CV) from a domestic dehumidifier. The compressor was designed for use with R134a, and in this work, it was tested with R1234yf and R290 without hardware modification to investigate the use of these refrigerants as drop-in replacements. Testing was conducted using a dedicated compressor calorimeter under controlled suction temperatures, and saturated condensing temperatures, which are representative of domestic scale dehumidifier operation. Experimental data were used to populate a compressor sub-model to predict isentropic efficiency, volumetric efficiency, and fractional heat loss, with good agreement observed between the measured data and the empirical model data. Performance surfaces are presented to compare refrigerant-dependent operating behaviour.
Isentropic efficiency peaks were broadly comparable across all three refrigerants (0.43-0.46), however, the shape of the isentropic efficiency surface differed markedly for each refrigerant. The isentropic efficiency of R134a exhibited a dome-shaped surface with a well-defined interior optimum consistent with its role as the design refrigerant. R1234yf produced a declining isentropic efficiency surface, with isentropic efficiency decreasing as both pressure ratio and condensing pressure increased, suggesting the compressor's efficiency optimum lies outside the tested operating range when charged with this refrigerant. R290 produced a saddle-shaped surface with compressed efficiency variation, suggesting greater robustness to changing conditions. R1234yf achieved the highest peak volumetric efficiency (0.93-0.95) but was the most condition-sensitive refrigerant, with performance declining steeply as pressure ratio increased. R290 exhibited the lowest volumetric efficiency (0.82-0.88) as a consequence of its higher absolute operating pressures, though this penalty is partially offset by its superior volumetric refrigeration capacity. Fractional heat loss was broadly comparable across all three refrigerants (0.15-0.27), simplifying thermal loss modelling when switching refrigerants in system-level simulations.
Documents disponibles
Format PDF
Pages : 12 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Calorimetric Performance Evaluation of a Small R134a Rotary Compressor Using R1234yf, and R290
- Identifiant de la fiche : 30035482
- Langues : Anglais
- Sujet : Technologie
- Source : 17th IIR-Gustav Lorentzen Conference on Natural Refrigerants. Proceedings. Hamilton, New Zealand, August 23-26 2026.
- Date d'édition : 08/2026
- DOI : http://dx.doi.org/10.18462/iir.gl2026.0088
Liens
Voir d'autres communications du même compte rendu (91)
Voir le compte rendu de la conférence
Indexation
- Thèmes : N/A
- Mots-clés : N/A