Résumé
The benefits of applying automated fault detection and diagnosis (AFDD) to chillers include less expensive repairs, timely maintenance, and shorter downtimes. This study employs feature selection (FS) techniques, such as mutual-information-based filter and genetic-algorithm-based wrapper, to help search for the important sensors in data driven chiller FDD applications, so as to improve FDD performance while saving initial sensor cost. The 'one-against-one' multi-class support vector machine (SVM) is adopted as a FDD tool. The results show that the eight features/sensors, centered around the core refrigeration cycle and selected by the GA-SVM wrapper from the original 64 features, outperform the other three feature subsets by the GA-LDA (linear discriminant analysis) wrapper, with an overall classification correct rate (CR) as high as 99.53% for the 4000 test samples randomly covering the normal and seven typical faulty modes. The CRs for the four cases with FS are all higher than that without FS (97.45%) and the test time is much less, about 28-36%. The FDD performance for normal or each of the faulty modes is also evaluated in details in terms of hit rate and false alarm rate.
Documents disponibles
Format PDF
Pages : pp. 586-599
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Important sensors for chiller fault detection and diagnosis (FDD) from the perspective of feature selection and machine learning.
- Identifiant de la fiche : 2010-1852
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 2
- Date d'édition : 03/2011
Liens
Voir d'autres articles du même numéro (18)
Voir la source
Indexation
-
Etude expérimentale sur la performance d'un pro...
- Auteurs : LI Z., ZHANG G., LI L., et al.
- Date : 04/2007
- Langues : Chinois
- Source : HV & AC - vol. 37 - n. 197
- Formats : PDF
Voir la fiche
-
Study on the support vector data description (S...
- Auteurs : LI G., HU Y., CHEN H., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Development and evaluation of a simple model-ba...
- Auteurs : REDDY T. A.
- Date : 23/06/2007
- Langues : Anglais
- Source : ASHRAE Transactions. 2007 Annual Meeting, Long Beach, CA. Volume 113, part 2 + CD-ROM.
Voir la fiche
-
A vapour compression chiller fault detection te...
- Auteurs : NAVARRO-ESBRÍ J., TORRELLA E., CABELLO R.
- Date : 08/2006
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 29 - n. 5
- Formats : PDF
Voir la fiche
-
Méthode d'évaluation qualimétrique du degré de ...
- Auteurs : VENGER K. P., FES'KOV O. A., ZIL'COV I. B., et al.
- Date : 2008
- Langues : Russe
- Source : Kholodilnaya Tekhnika - n. 2
Voir la fiche