Document IIF

Caractérisation de refroidissement d'un refroidisseur cryogénique Joule-Thomson conceptuel.

Cooling characterization of conceptual Joule-Thomson cryogenic cooler.

Numéro : pap. 27

Auteurs : CAN F., ERDOGMUS A. B., BAKI M., et al.

Résumé

In this study, cooling characterization of a conceptual Joule-Thomson cryogenic cooler operating with argon or nitrogen gases as coolant is studied by using numerical approach. Because of geometric complexities, a one dimensional model is used to study the thermo-fluidic behavior of the system. Heat transfer correlations used in the previous investigations are used while the thermodynamic properties of selected real gases are calculated by utilizing an inhouse code based on formulations presented in the literature. In most of the previous studies, the same friction factor formulation is used in pressure loss calculations. In this study,
pressure drop is calculated through a different approach. The major distinction of present study is related to pressure drop calculations. Since the model is one dimensional, finite difference method is applied to solve differential form of governing equations. Numerical results are validated with the results published in the literature and satisfactory agreement is obtained.

Documents disponibles

Format PDF

Pages : 8

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Cooling characterization of conceptual Joule-Thomson cryogenic cooler.
  • Identifiant de la fiche : 30018361
  • Langues : Anglais
  • Source : 1st IIR International Conference of Cryogenics and Refrigeration Technology (ICCRT 2016). Proceedings: Bucharest, Romania, June 22-25, 2016.
  • Date d'édition : 22/06/2016
  • DOI : http://dx.doi.org/10.18462/IIR.ICCRT.2016.0027

Liens


Voir d'autres communications du même compte rendu (32)
Voir le compte rendu de la conférence