Caractérisation hydraulique des circuits de refroidissement pour les câbles conducteurs en conduits (CICC) de l'ITER.

Hydraulic characterisation of ITER CICC cooling inlets.

Auteurs : DECOOL P., CLOEZ H., SERRIES J. P., et al.

Résumé

The cooling of ITER cable in conduit conductors (CICC) is insured by supercritical helium forced flow in the central and annular parallel channels. The helium inlets are in the most critical highest field region at the inner bore pancake joggle. They have to ensure a low pressure drop as well as a balanced flow repartition among sub-cables. Two different designs were proposed adapted to the specificities of the CS and TF coils conductors. Mock-ups were manufactured and qualified using GN2 at relevant Reynolds number. These hydraulic results are presented and analysed.

Documents disponibles

Format PDF

Pages : 2006-3/ICEC I-A3

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Hydraulic characterisation of ITER CICC cooling inlets.
  • Identifiant de la fiche : 2008-0492
  • Langues : Anglais
  • Source : Multiconference CryoPrague 2006 (9th Cryogenics 2006, ICEC 21, ICMC'06)
  • Date d'édition : 17/07/2006

Liens


Voir d'autres communications du même compte rendu (142)
Voir le compte rendu de la conférence