Résumé
Linear compressors have been widely used in the cryocoolers and refrigerators due to the advantages of high efficiency, low vibration level and compact construction. However, due to the complicated dynamic characteristics of the linear compressor, the impedance matching of the cryocooler is still an issue. In this study, the operating characteristics of a linear compressor are studied based on the electrical and mechanical impedance. The influences of the load impedance on the displacement and efficiency are analyzed. A new efficiency map under the total impedance is proposed. Experiments on a pulse tube cryocooler with a linear compressor are conducted to verify the theoretical analyses. The maximum theoretical efficiency of 0.86 is obtained at 963+0i N s m−1. It is not affected by the displacement or the current. Two different routines by fixing the current at 20 A or fixing the voltage at 50 V are tested on the new efficiency map. The results show the feasibility of using the new map to find a better impedance matching and to achieve an efficiency of 0.68. The research is helpful to improve the whole cryocooler performance.
Documents disponibles
Format PDF
Pages : 215-223
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Operating characteristics of a linear compressor in the cryocooler.
- Identifiant de la fiche : 30028712
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 129
- Date d'édition : 09/2021
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2021.05.011
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres articles du même numéro (32)
Voir la source
Indexation
-
Effects of the driving voltage waveform on the ...
- Auteurs : TAN J., DANG H.
- Date : 03/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 75
- Formats : PDF
Voir la fiche
-
Study on connecting way of gas reservoir in a d...
- Auteurs : CHEN X., LIU S., LI Y., et al.
- Date : 07/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 91
- Formats : PDF
Voir la fiche
-
Coupling study of a novel thermocompressor driv...
- Auteurs : JI W., XUE X., WANG J., et al.
- Date : 03/2013
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 51 - n. 1-2
Voir la fiche
-
A high capacity completely closed-cycle 250 mK ...
- Auteurs : DEVLIN M. J., DICKER S. R., KLEIN J., et al.
- Date : 09/2004
- Langues : Anglais
- Source : Cryogenics - vol. 44 - n. 9
Voir la fiche
-
Impedance match for Stirling type cryocoolers.
- Auteurs : WEI D., ERCANG L., XIAOTAO W., et al.
- Date : 04/2011
- Langues : Anglais
- Source : Cryogenics - vol. 51 - n. 4
Voir la fiche