Document IIF
Caractéristiques de transfert de chaleur d'un mélange R-410A/huile en ébullition libre à l'intérieur d'un tube droit (d'un diamètre de 7 mm) à micro-ailettes.
Heat transfer characteristics of R-410A/oil mixture flow boiling inside a 7 mm straight microfin tube.
Résumé
Two-phase heat transfer characteristics of R-410A-oil mixture flow boiling inside a straight microfin tube with the outside diameter of 7.0 mm were investigated experimentally. The experimental conditions include the evaporation temperature of 5°C, the mass flux from 200 to 400 kg/m2.s, the heat flux from 7.56 to 15.12 kW/m2, the inlet vapour quality from 0.2 to 0.7, and nominal oil concentration from 0 to 5%. The test results show that the heat transfer coefficient of R-410A-oil mixture increases with mass flux of refrigerant- oil mixture; the presence of oil enhances the heat transfer at the range of low vapour qualities); while at high vapour qualities, the presence of oil deteriorates heat transfer, and the heat transfer coefficient drops off very sharply with the increase of nominal oil concentration and vapour quality at high vapour qualities. A new correlation to predict the local heat transfer coefficient of R-410A/oil mixture flow boiling inside the straight microfin tube was developed based on local properties of refrigerant- oil mixture, and it could agree with 89% of the experimental data within the deviation of plus or minus 30%.
Documents disponibles
Format PDF
Pages : 1081-1093
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Heat transfer characteristics of R-410A/oil mixture flow boiling inside a 7 mm straight microfin tube.
- Identifiant de la fiche : 2008-2450
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 6
- Date d'édition : 09/2008
Liens
Voir d'autres articles du même numéro (17)
Voir la source
Indexation
-
Local heat transfer coefficients during boiling...
- Auteurs : LALLEMAND M., BRANESCU C., HABERSCHILL P.
- Date : 01/2001
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 24 - n. 1
- Formats : PDF
Voir la fiche
-
Experimental investigation and correlation of t...
- Auteurs : DING G., HU H., HUANG X., et al.
- Date : 01/2009
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 1
- Formats : PDF
Voir la fiche
-
Measurement and correlation of frictional two-p...
- Auteurs : HU H. T., DING G. L., WANG K. J.
- Date : 08/2008
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 28 - n. 11-12
Voir la fiche
-
Condensation heat transfer and pressure drop in...
- Auteurs : LEE E. J., KIM N. H., BYUN H. W.
- Date : 02/2014
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 38
- Formats : PDF
Voir la fiche
-
Evaporation of R407C and R410A in a horizontal ...
- Auteurs : WELLSANDT S., VAMLING L.
- Date : 09/2005
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 28 - n. 6
- Formats : PDF