Caractéristiques des pertes de frigorigène et d'huile dues aux fuites dans un système de conditionnement d'air.
Characteristics of refrigerant and oil losses due to a leakage in air conditioning system.
Auteurs : YUN K. W.
Résumé
Once leakage occurs refrigerant and oil escape from the system and compressor. The paper determines the characteristics of the losses. Two important factors are location of leakage in the system and speed of leakage or leakage rate. The paper then analyzes the tested actual loss characteristics. Impact of oil loss from rotary compressor is reviewed from the standpoints of reliability and protection of compressor as a function of the two factors.
Détails
- Titre original : Characteristics of refrigerant and oil losses due to a leakage in air conditioning system.
- Identifiant de la fiche : 2001-1723
- Langues : Anglais
- Source : Proceedings of the 2000 International Compressor Engineering Conference at Purdue.
- Date d'édition : 25/07/2000
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (66)
Voir le compte rendu de la conférence
Indexation
-
Le R32 : un frigorigène du futur pour les condi...
- Auteurs : YAMAGUCHI H.
- Date : 07/12/2000
- Langues : Japonais
- Source : The International Symposium on HCFC Alternative Refrigerants and Environmental Technology 2000: Latest technology for Energy Conservation, Refrigerants and Recycling on Air-Conditioning and Refrigeration Equipment for the 21st century. Proceedings.
Voir la fiche
-
Dispersion of flammable refrigerants from split...
- Auteurs : COLBOURNE D., BUTLER D.
- Date : 25/07/2000
- Langues : Anglais
- Source : Final proceedings of the 4th IIR-Gustav Lorentzen Conference on Natural Working Fluids at Purdue.
- Formats : PDF
Voir la fiche
-
Refrigerant leakage control for R-290 in split ...
- Auteurs : COLBOURNE D., HÜHREN R., RAJADHYAKSHA D. D., et al.
- Date : 02/09/2013
- Langues : Anglais
- Source : Compressors 2013: 8th International Conference on Compressors and Coolants.
- Formats : PDF
Voir la fiche
-
Fault diagnosis of refrigerant charge based on ...
- Auteurs : LIU J., CHEN H., WANG J., et al.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
R290 leakage mass flow rate from a refrigeratin...
- Auteurs : COLBOURNE D., LIU Z. X.
- Date : 25/06/2012
- Langues : Anglais
- Source : 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Formats : PDF
Voir la fiche