Caractéristiques du tube à pulsation à double entrée.

Characteristics of the double inlet pulse tube.

Auteurs : BOER P. C. T. de

Type d'article : Article

Résumé

The performance of the double inlet pulse tube (DIPT) is analysed using a linearized model that takes account of the void volume of the regenerator. The maximum rate of refrigeration obtainable with the regenerator is determined as a function of frequency and void volume. The results obtained for the DIPT are compared with corresponding results for the optimized orifice pulse tube refrigerator (OPTR). The large improvements in performance obtained with the DIPT over the OPTR are due primarily to an increase in the pulse tube pressure. The maximum rate of refrigeration decreases as the temperature at the cold side decreases. This is caused primarily from the resulting decrease in cold side flow rate. At given temperature ratio, addition of the second inlet reduces the flow rate through the regenerator over a range of intermediate frequencies.

Détails

  • Titre original : Characteristics of the double inlet pulse tube.
  • Identifiant de la fiche : 2005-0001
  • Langues : Anglais
  • Source : Cryogenics - vol. 43 - n. 7
  • Date d'édition : 07/2003

Liens


Voir d'autres articles du même numéro (1)
Voir la source