Caractéristiques thermiques de pieux de fondation en acier utilisés comme échangeurs de chaleur par le sol.

Thermal characteristics of steel foundation piles as ground heat exchangers.

Auteurs : NAGANO K., KATSURA T., TAKEDA S., et al.

Résumé

Thermal characteristics are evaluated in the ground thermal energy system with steel foundation piles. Two kinds of field measurements are conducted in different places in cold regions of Japan. In the first one, the use of a double U-tube results in the equivalent heat extraction per unit length of the ground heat exchangers compared to that in a direct circulating heat exchange even in the case with a steel pile of a large diameter of 400 mm. The average effective heat conductivity of the surrounding soil is also estimated to be 1.5 W/m.K. The other measurements using multiple steel piles demonstrate the heating output enough to cover the whole heating demand in the regions.

Détails

  • Titre original : Thermal characteristics of steel foundation piles as ground heat exchangers.
  • Identifiant de la fiche : 2006-3178
  • Langues : Anglais
  • Source : 8th IEA Heat Pump Conference 2005: global advances in heat pump technology, applications, and markets. Conference proceedings [CD-ROM].
  • Date d'édition : 02/05/2005

Liens


Voir d'autres communications du même compte rendu (57)