Collecte des condensats à partir de grands systèmes de traitement de l'air extérieur avec récupération de chaleur.
Condensate harvesting from large dedicated outside air-handling units with heat recovery.
Auteurs : PAINTER F. L.
Résumé
This paper shows the feasibility of harvesting condensate from large dedicated outdoor air handling units and applying the condensate to effectively reduce the annual projected potable water consumption for a case study building. Condensate production potentials are calculated for three areas in Texas; San Antonio, Houston, and Dallas/Fort Worth. A case study building is presented, for which the production potential is applied. The case study building annual condensate production as well as the annual potable water consumption for the water closets and urinals and cooling tower makeup water is calculated and presented to compare condensate supply and potable water demand. The case study building, which is a medical research laboratory located in San Antonio, TX, was determined to have an annual condensate production of 1 887 031 gallons, which would normally be sent to the sanitary sewer system. The analysis indicates that the condensate production from the case study building's large dedicated outdoor air handling units can completely supplement the annual water closet and urinal water demand with 1 614 031 gallons of excess, which could be used to supplement landscape irrigation system or the entire condensate production could be applied to reduce the cooling tower makeup potable water demand by an estimated 16%.
Détails
- Titre original : Condensate harvesting from large dedicated outside air-handling units with heat recovery.
- Identifiant de la fiche : 2010-0182
- Langues : Anglais
- Source : 2009 ASHRAE Annual Conference CD. Transactions papers presented at the 2009 ASHRAE Annual Conference: Louisville, KY, June 2009. Volume 115, part 2.
- Date d'édition : 21/06/2009
Liens
- Liens externes :
Voir d'autres communications du même compte rendu (30)
Voir le compte rendu de la conférence
-
Qualità dell'aria ed efficienza degli impianti:...
- Auteurs : CARANO C.
- Date : 08/10/2009
- Langues : Italien
- Source : Impianti, energia e ambiente costruito: verso un benessere sostenibile. Atti 47° Congresso Internazionale AICARR: 8-9 ottobre 2009, Tivoli-Roma./ Systems, energy and built environment: toward a sustainable comfort. Proceedings 47th International Congress of AICARR: October 8-9, 2009, Tivoli-Rome.
- Formats : PDF
Voir la fiche
-
Best practice examples of reduced power consump...
- Auteurs : BRADWELL S.
- Date : 18/09/2008
- Langues : Anglais
- Source : HVAC Energy Efficiency Best Practice Conference
- Formats : PDF
Voir la fiche
-
Validation of a run-around heat recovery system...
- Auteurs : BENNETT I. J. D., BESANT R. W., SCHOENAU G. J.
- Date : 1994
- Langues : Anglais
- Source : Heat pumps in cold climates. Proceedings of the second international technical conference.
Voir la fiche
-
Introduction to heat recovery chiller control a...
- Auteurs : JIA J.
- Date : 05/04/2008
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR'2008.
Voir la fiche
-
Comparativa del potencial de recuperación de en...
- Auteurs : RUIZ R., RIBÉ O., QUERA M., et al.
- Date : 19/06/2018
- Langues : Espagnol
- Source : CYTEF 2018. IX Congreso Ibérico y VII Congreso Iberoamericano de Ciencias y Técnicas del Frío, Valencia, España, 19-21 junio 2018.
- Formats : PDF
Voir la fiche