Commande algébrique robuste d’un système de chauffage et de refroidissement en circuit fermé avec un échangeur de chaleur et des temps de réponse internes de la boucle.
Algebraic robust control of a closed circuit heating-cooling system with a heat exchanger and internal loop delays.
Résumé
This study demonstrates the use of a simple algebraic controller design for a cooling-heating plant with a through-flow air-water heat exchanger that evinces long internal delays with respect to the robustness to plant model uncertainties and variable ambient temperature conditions during the season. The advantage of the proposed design method consists in that the delays are not approximated but fully considered. Moreover, the reduction of sensitivity to model parameters’ variations yields the better applicability regardless modeling errors or environmental fluctuations. The infinite-dimensional mathematical model of the plant has been obtained by using anisochronic modeling principles. The key tool for the design is the ring special of quasipolynomial meromorphic functions (RQM). The Two-Feedback-Controllers (TFC) rather than the simple negative control feedback loop is utilized, which enables to solve the reference tracking and disturbance rejection independently and more efficiently. The eventual controller is then tuned such that robust stability and robust performance requirements are fulfilled. The tuning procedure is supported by a performance optimization idea. Since the originally obtained controller is of the infinite-dimensional nature, a possible way how to substitute it by a simplified finite-dimensional one is proposed for engineering practice. The functionality of both the controllers is compared and verified by simulations as well as by real measurements which prove a very good performance.
Détails
- Titre original : Algebraic robust control of a closed circuit heating-cooling system with a heat exchanger and internal loop delays.
- Identifiant de la fiche : 30021073
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 113
- Date d'édition : 25/02/2017
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2016.11.150
Liens
Voir d'autres articles du même numéro (24)
Voir la source
Indexation
-
Numerical study on the long-term performance an...
- Auteurs : WANG R., WANG F., XUE Y., JIANG J., ZHANG Y., CAI W., CHEN C.
- Date : 05/2022
- Langues : Anglais
- Source : Energies - vol. 15 - n. 9
- Formats : PDF
Voir la fiche
-
Flow instability of evaporative microchannels.
- Auteurs : LEE H. J., LIU D. Y., YAO S. C.
- Date : 04/2010
- Langues : Anglais
- Source : International Journal of Heat and Mass Transfer - vol. 53 - n. 9-10
Voir la fiche
-
Numerical study on thermal hydraulic performanc...
- Auteurs : SAEED M., KIM M. H.
- Date : 09/2016
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 69
- Formats : PDF
Voir la fiche
-
Performance analysis of ground source heat pump...
- Auteurs : CHAE H., NAGANO K., SAKATA Y., KATSURA T., KONDO T.
- Date : 31/08/2021
- Langues : Anglais
- Source : 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
Voir la fiche
-
How to design & control waterside economizers.
- Auteurs : TAYLOR S. T.
- Date : 06/2014
- Langues : Anglais
- Source : ASHRAE Journal - vol. 56 - n. 6