Document IIF
Comparaison analytique entre le R134a et des frigorigènes de substitution dans un refroidisseur refroidi par eau.
An analytical comparison between R134a and alternative refrigerants in the water-cooled chiller.
Numéro : 1066
Résumé
Owing to escalating effect of global warming on climate change, the replacement of HFCs using lower GWP refrigerants has become a crucial work to reduce the predicted increase of mean surface temperature of the Earth. In the current scenario, this paper presents a water-cooled chiller cycle analysis to identify the relative performance of R134a, potential substitutions R513A, R1234yf, R1234ze(E), and low-pressure refrigerants R1233zd(E) and R1224yd(Z) for a 200RT chiller application. Comparisons between R134a and alternative refrigerants are carried out in terms of coefficient of performance, exergy efficiency, and irreversibility under the three types of working conditions: constant refrigerant volumetric flowrate, constant cooling capacity and fixed refrigerant mass flowrate. For constant volumetric flowrate condition, R513A can be a drop-in substitute for R134a chiller. In the constant cooling capacity and fixed mass flowrate condition, R1234ze(E) has the similar performance to R134a and performance of low-pressure refrigerants R1233zd(E) and R1224yd(Z) is better than that of R134a.
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : An analytical comparison between R134a and alternative refrigerants in the water-cooled chiller.
- Identifiant de la fiche : 30028826
- Langues : Anglais
- Sujet : Technologie, Alternatives aux HFC
- Source : 2nd IIR Conference on HFO Refrigerants and Low GWP Blends
- Date d'édition : 06/2021
- DOI : http://dx.doi.org/10.18462/iir.HFO.2021.1066
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (52)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
HFC;
HFO et HCFO;
Mélanges;
Refroidisseurs d'eau - Mots-clés : R134a; Faible GWP; Refroidisseur d'eau; R1234yf; R513A; R1234ze(E); R1233zd(E); R1224yd(Z); Exergie; Puissance frigorifique; COP; Cycle thermodynamique; Modélisation; Performance
-
An update on the thermophysical properties data...
- Auteurs : FEDELE L., BOBBO S., MENEGAZZO D.
- Date : 01/09/2021
- Langues : Anglais
- Source : 6th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
Voir la fiche
-
Review of next generation low GWP refrigerants ...
- Auteurs : KUJAK S., SCHULTZ K.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Thermodynamic analysis of low GWP HFO and HCFO ...
- Auteurs : DIEWALD K., ARPAGAUS C., HEBENSTREIT B.
- Date : 31/07/2020
- Langues : Anglais
- Source : IIR Rankine Conference 2020.
- Formats : PDF
Voir la fiche
-
Review of ultra-low GWP molecules – thermodynam...
- Auteurs : KUJAK S., SCHULTZ K., SORENSON E.
- Date : 31/07/2020
- Langues : Anglais
- Source : IIR Rankine Conference 2020.
- Formats : PDF
Voir la fiche
-
Heat transfer assessment of the low gwp substit...
- Auteurs : RIGHETTI G., LONGO G. A., MANCIN S., ZILIO C.
- Date : 31/07/2020
- Langues : Anglais
- Source : IIR Rankine Conference 2020.
- Formats : PDF
Voir la fiche