Comparaison des performances du R-134a, du R-1234yf et du R-600a dans un système frigorifique à pulvérisation de taille compacte pour le refroidissement de composants électroniques.
Comparing the performances of R-134a, R-1234yf and R-600a in a compact spray refrigeration system for electronics cooling.
Auteurs : CARNEIRO M. V. P., BARBOSA J. R. Jr
Type d'article : Article de la RIF
Résumé
The multi-jet spray cooling unit, integrated with a compact, linear, oil-free R-134a compressor introduced in previous work, is now experimentally evaluated with R-1234yf and R-600a as drop-in replacement alternatives. This unit combines the functions of the evaporator and the expansion device into a single device, allowing the subcooled refrigerant to expand through an array of oblique orifices and form a spray that directly impinges on the heated surface. The experimental analysis quantifies the cooling system hermodynamic performance, including compressor power and coefficient of performance, as well as steady-state heat transfer parameters such as heat transfer coefficient, surface temperature, and critical heat flux. The evaluation considers the influence of refrigerant charge, steady-state applied thermal load (cooling capacity), and refrigerant type. To ensure an unbiased comparison, the refrigerant charge is adjusted so that all refrigerants maintain the same evaporating temperature at the lowest thermal load of 25 W. Experimental tests are conducted across a wide range of evaporation temperatures (4.5 to 20.0 ◦C). The results indicate a trade-off between heat transfer performance and thermodynamic performance of the refrigeration system when selecting a refrigerant alternative. R-600a required the lowest refrigerant charge to achieve the reference evaporation temperature and exhibited the lowest refrigerant mass flow rate under all tested conditions. However, the heat transfer performance of R-600a is severely penalized compared to R-134a and R-1234yf, with approximately a 40% reduction in the maximum heat transfer coefficient. The maximum values of the heat transfer coefficient for R-134a, R-1234yf, and R-600a are 42.9, 43.4, and 25.8 kW/m2 K, respectively.
Documents disponibles
Format PDF
Pages : 12 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Comparing the performances of R-134a, R-1234yf and R-600a in a compact spray refrigeration system for electronics cooling.
- Identifiant de la fiche : 30034240
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 175
- Date d'édition : 07/2025
- DOI : http://dx.doi.org/https://doi.org/10.1016/j.ijrefrig.2025.03.048
Liens
Voir d'autres articles du même numéro (34)
Voir la source
Indexation
- Thèmes : N/A
- Mots-clés : N/A