Comparaison des performances exergo-économiques du R1234yf comme substitut immédiat au R134A dans un réfrigérateur domestique.
Exergoeconomic performance comparison of R1234yf as a drop-in replacement for R134a in a domestic refrigerator.
Auteurs : RANGEL-HERNANDEZ V. H., BELMAN-FLORES J. M., RODRIGEZ-VALDERRAMA D. A., et al.
Type d'article : Article, Article de la RIF
Résumé
The replacement of refrigerants in domestic refrigerators is nowadays one of the approaches used to enhance the performance and environmental impact of these systems. Theoretical and experimental research, mainly focused on energy or exergy analysis, is currently found in the literature, but only a few studies are focused on exergoeconomic approaches. Therefore, in order to include the overall costs of a domestic refrigerator, an exergoeconomic cost analysis is applied to an experimental installation. Exergoeconomic parameters such as the unit exergy cost (cp) and the exergoeconomic factor (f) are used as a comparative indicator of performance. Based on the unit exergy cost, the results show that R134a performs better than R1234yf at different operating conditions. The exergoeconomic factor presents higher values for R134a than for R1234yf, which implies less exergy destruction in the system. The optimization allows reducing the cost of the produced cold by 9.8% when using R134a and by 6.5% when using R1234yf.
Documents disponibles
Format PDF
Pages : 113-123
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Exergoeconomic performance comparison of R1234yf as a drop-in replacement for R134a in a domestic refrigerator.
- Identifiant de la fiche : 30025606
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 100
- Date d'édition : 04/2019
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2019.01.016
Liens
Voir d'autres articles du même numéro (46)
Voir la source
-
Experimental performance of R-1234yf and R-1234...
- Auteurs : KARBER K. M., ABDELAZIZ O., VINEYARD E. A.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Improving energy efficiency of built-in refrige...
- Auteurs : GEPPERT J., STAMMINGER R.
- Date : 23/06/2014
- Langues : Anglais
- Source : 3rd IIR International Conference on Sustainability and the Cold Chain. Proceedings: London, UK, June 23-25, 2014
- Formats : PDF
Voir la fiche
-
An experimental investigation of the energetic ...
- Auteurs : APREA C., GRECO A., MAIORINO A.
- Date : 04/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 76
- Formats : PDF
Voir la fiche
-
L'emploi des éjecteurs dans les réfrigérateurs ...
- Auteurs : LAWRENTSCHKO G. K., KHMELNUK M. G.
- Date : 11/1992
- Langues : Allemand
- Source : Kälte + Klimatechnik (Die) - vol. 45 - n. 11
Voir la fiche
-
The effect of selecting proper refrigeration cy...
- Auteurs : GHADIRI F., RASTI M.
- Date : 06/2014
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 67 - n. 1-2
Voir la fiche