Comparaison expérimentale des performances saisonnières d’un refroidisseur au R410A utilisant un compresseur bi-étagé et à vitesse unique.
Experimental comparison of seasonal performance in R410A chiller using single speed and two stage compressor.
Numéro : 1484
Auteurs : INAMPUDI S. T., BOTTICELLA F., ELBEL S.
Résumé
Rising cooling needs for the residential and commercial air conditioning sectors and the requirement of higher SEER values increased the focus on energy-efficient part load performance. Although several studies exist on the topic of capacity modulation, there is no comprehensive study that compares different modulation strategies in the same experimental facility. In a first step, this paper aims to experimentally compare two different capacity controls for scroll compressors (single speed vs two-stage compressor) using the same R410A water ethylene glycol (WEG) chiller having a nominal cooling capacity of 8kW. The tests were conducted according to AHRI Standard 551/591 (2018). The Integrated Part Load Value (IPLV.SI) was used to fairly compare all these capacity modulation strategies. Based on the experimental results, the difference in the order of 8% in IPLV.SI is found. While both compressors showed comparable capacities and COPs at the higher modulation conditions, two stage compressor has better COP at the lower condition because of its ability to operate at a lower stage and better meet the required load.
Documents disponibles
Format PDF
Pages : 9
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental comparison of seasonal performance in R410A chiller using single speed and two stage compressor.
- Identifiant de la fiche : 30028384
- Langues : Anglais
- Sujet : Technologie
- Source : 2021 Purdue Conferences. 25th International Compressor Engineering Conference at Purdue.
- Date d'édition : 05/2021
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (62)
Voir le compte rendu de la conférence
Indexation
-
Seasonal energy efficiency rating improvement o...
- Auteurs : CHRETIEN L., BECERRA R., SALTS N., et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Amélioration de la performance d'un conditionne...
- Auteurs : NAKAMURA H., YOKOYAMA H., NONAKA M., et al.
- Date : 06/2011
- Langues : Japonais
- Source : Refrigeration - vol. 086 - n. 1004
Voir la fiche
-
R32 scroll compressors technology.
- Auteurs : YAN C., XU H., GINIES P., et al.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 21st International Compressor Engineering Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Performance of a state-of-art packaged heat pum...
- Auteurs : KUMAR N., GUADA A., ASHER W., FRIDLYAND A., GLANVILLE P., BLAYLOCK M., STRONG T.
- Date : 15/05/2023
- Langues : Anglais
- Source : 14th IEA Heat Pump Conference 2023, Chicago, Illinois.
- Formats : PDF
Voir la fiche
-
Modeling a scroll compressor using a Cartesian ...
- Auteurs : ROWINSKI D., PHAM H., BRANDT T.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 24th International Compressor Engineering Conference at Purdue.
- Formats : PDF
Voir la fiche