Comportement dynamique d'un évaporateur à détente directe sous des conditions de givrage. II. Etude sur le terrain portant sur un conteneur maritime.

Dynamic behaviour of a direct expansion evaporator under frosting condition. II. Field investigation on a shipping container.

Auteurs : TSO C. P., CHENG Y. C., LAI A. C. K.

Type d'article : Article, Article de la RIF

Résumé

A field investigation is performed on the frost formation at an evaporator of a commercial full-scale refrigerated container that uses R12 as the working refrigerant. Results, when compared with those from a numerical model presented earlier (see this Bulletin, reference 2006-1677), show that the model is capable of predicting the dynamic behaviour of a direct expansion evaporator under both non-frosting and frosting conditions. The air outlet and energy transferred compare well between experiment and model, and within 20% for the air pressure drop. The frost occurrence and propagation agree well generally, with the frost formation first occurring at the first row where the refrigerant enters the evaporator.

Documents disponibles

Format PDF

Pages : 624-631

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Dynamic behaviour of a direct expansion evaporator under frosting condition. II. Field investigation on a shipping container.
  • Identifiant de la fiche : 2006-1681
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 29 - n. 4
  • Date d'édition : 06/2006