Many problems will arise when a R12 refrigerator compressor uses R134a as refrigerant directly, including increased power consumption, decreased capacity, and higher noise levels, etc. In order to solve these problems, improvements were made by means of mathematical models and tests. Finally, the performance of the R134a refrigerator compressor wais greatly improved, having become much higher than that of the original compressor. Long-term operation indicates that the sample compressor works well.

Détails

  • Titre original : Performance improvement of R134a refrigerator compressor.
  • Identifiant de la fiche : 2001-1819
  • Langues : Anglais
  • Source : Proceedings of the 2000 International Compressor Engineering Conference at Purdue.
  • Date d'édition : 25/07/2000
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.