CONCEPTION DES POMPES A CHALEUR POUR LES SYSTEMES D'ACCUMULATION D'ENERGIE THERMIQUE SAISONNIERE DANS LA NAPPE PHREATIQUE POUR LE CHAUFFAGE SEUL.

HEAT PUMP DESIGN FOR AQUIFER SEASONAL HEATING-ONLY THERMAL ENERGY STORAGE SYSTEMS.

Résumé

L'ACCUMULATION D'ENERGIE THERMIQUE SAISONNIERE DANS LA NAPPE PHREATIQUE EST CONSIDEREE EN LIAISON AVEC LES POMPES A CHALEUR A SOURCE D'EAU POUR LE CHAUFFAGE DES LOCAUX RESIDENTIELS. LE SYSTEME ETUDIE CONSISTE EN UNE NAPPE PHREATIQUE LIMITEE, COMPORTANT DEUX PUITS (INJECTION ET PRODUCTION) ET DE NOMBREUSES POMPES A CHALEUR RELIEES PAR UN RESEAUDE DISTRIBUTION. ON A MIS AU POINT UN MODELE DU SYSTEME. LA MODELISATION ET L'EVALUATION DU SYSTEME MONTRENT COMMENT LA POSSIBILITE DE RENDEMENT ENERGETIQUE DE CES SYSTEMES DEPEND D'UN CERTAIN NOMBRE DE VARIABLES GEOLOGIQUES, GEOPHYSIQUES, D'INGENIERIE, ARCHITECTURALES ET CLIMATIQUES. LES RESULTATS MONTRENT QUE LE SYSTEME DE RECHARGE, INDEPENDAMMENT DE LA SOURCE D'ENERGIE THERMIQUE, PEUT AVOIR UNE INFLUENCE NETTE SUR LA POSSIBILITE DE RENDEMENT ENERGETIQUE DE CES SYSTEMES. POUR CERTAINS DOMAINES DE PARAMETRES, CES SYSTEMES PRESENTENT UNE BONNE POSSIBILITE DE RENDEMENT ENERGETIQUE, A CONDITION QU'ON DISPOSE DUE A UTILISER DANS LA RECHARGE.

Détails

  • Titre original : HEAT PUMP DESIGN FOR AQUIFER SEASONAL HEATING-ONLY THERMAL ENERGY STORAGE SYSTEMS.
  • Identifiant de la fiche : 1986-0386
  • Langues : Anglais
  • Date d'édition : 1984
  • Source : Source : ASHRAE Trans.
    vol. 90; n. 2B; 119-136; 23 fig.; 2 tabl.; 10 ref.
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.