CONCEPTION NORMALISEE D'UN THERMOSTAT EN VUE DE LA REDUCTION DU FONCTIONNEMENT DES POMPES A CHALEUR PENDANT LA NUIT.

RULE-BASED THERMOSTAT DESIGN FOR NIGHT SETBACK OF HEAT PUMPS.

Auteurs : RUTZ A. L., MORAN M. J.

Type d'article : Article

Résumé

LES AUTEURSPRESENTENT UN MODELE POUR ORDINATEUR EN VUE DE L'ESSAI DE LA PERFORMANCE D'UN THERMOSTAT POUR POMPE A CHALEUR A DECALAGE NOCTURNE DU POINT DE CONSIGNE DU POINT DE VUE DES ECONOMIES D'ENERGIE ET DE COUT RETIREES D'UNE REDUCTION DU FONCTIONNEMENT PENDANT LA NUIT. IL PRESENTE AUSSI 2 NOUVELLES STRATEGIES DE REGULATION POUR LA REDUCTION DU FONCTIONNEMENT DES POMPES A CHALEUR PENDANT LA NUIT : UNE VARIATION PEU COUTEUSE DES STRATEGIES DE REGULATION EXISTANTES ET UNE STRATEGIE DE REGULATION NORMALISEE UTILISANT DES TECHNIQUES D'INTELLIGENCE ARTIFICIELLE. LE MODELE POUR ORDINATEUR S'APPUIE SUR UN MODELE DE SYSTEME TRANSITOIRE DE LOGEMENT, DE POMPE A CHALEUR ET DE REGLEUR CORRESPONDANT AUX DONNEES METEOROLOGIQUES REELLES. LA CONSOMMATION SAISONNIERE D'ENERGIE ET LES COUTS SONT CALCULES POUR CHAQUE STRATEGIE DE REGULATION, VARIANT SUIVANT LE DIMENSIONNEMENT DES POMPES A CHALEUR, L'INERTIE THERMIQUE DES BATIMENTS, TION ELECTRIQUE.(PASCAL, Bibliogr. int., ENERG., FR., N 2, 1991, 943.

Détails

  • Titre original : RULE-BASED THERMOSTAT DESIGN FOR NIGHT SETBACK OF HEAT PUMPS.
  • Identifiant de la fiche : 1992-0794
  • Langues : Anglais
  • Source : Far and Near in Water & Energy - vol. 15 - n. 11
  • Date d'édition : 1990

Liens


Voir la source