Document IIF
Conditions du frigorigène à l’entrée du tube capillaire d’un réfrigérateur domestique.
Refrigerant conditions at the capillary tube inlet of a household refrigerator.
Numéro : pap. 1344
Auteurs : BARDOULET L., CORBERÁN J. M., BALLESTER S. M.
Résumé
Capillary tube-suction line heat exchanger (CT-SLHX) is a component widely used in household refrigerators. Recent works pointed out that even measuring subcooled conditions, the actual capillary tube inlet is two-phase flow. The main objective of this work is to visualize and assess experimentally the conditions taking place at the capillary tube inlet of a household refrigerator working with isobutane. The tube and wire condenser was replaced by a refrigerant-to-water heat exchanger in order to better assess the refrigerant conditions at the capillary tube inlet. Transparent tubes were set up at the condenser outlet and at the capillary tube inlet. The experiments confirmed the entrance of vapor and liquid in the capillary tube. Measurements indicated a non-equilibrium two-phase flow composed of subcooled vapor and liquid at the capillary tube inlet. The reason for the existence of two-phase flow seems to be the matching between the capillary tube and the compressor flow rates, meaning that the capillary tube is oversized. A smaller capillary tube diameter with different compressor speeds was tested, proving that at 2500 rpm the inlet of the capillary tube became full of liquid and clearly subcooled liquid conditions were measured.
Documents disponibles
Format PDF
Pages : 9
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Refrigerant conditions at the capillary tube inlet of a household refrigerator.
- Identifiant de la fiche : 30023680
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Date d'édition : 18/06/2018
- DOI : http://dx.doi.org/10.18462/iir.gl.2018.1344
Liens
Voir d'autres communications du même compte rendu (177)
Voir le compte rendu de la conférence
Indexation
-
Experimental study of R600a mass flow rate in n...
- Auteurs : RASTI M., HASAN M. R., JEONG J. H.
- Date : 13/06/2022
- Langues : Anglais
- Source : 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Formats : PDF
Voir la fiche
-
Integration of a mini-channel condenser into a ...
- Auteurs : TOSUN M., DOGAN B., ÖZTÜRK M., et al.
- Date : 02/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 98
- Formats : PDF
Voir la fiche
-
Mapping the energy consumption of household ref...
- Auteurs : BOENG J., MELO C.
- Date : 05/2014
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 41
- Formats : PDF
Voir la fiche
-
Mapping the energy consumption of household ref...
- Auteurs : BOENG J., MELO C.
- Date : 25/10/2012
- Langues : Anglais
- Source : RCR 2012. 3rd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems: Valencia, Spain, October 25-26, 2012.
- Formats : PDF
Voir la fiche
-
Performance evaluation of household refrigerato...
- Auteurs : ESPINDOLA R. S., KNABBEN F. T., MELO C., HERMES C. J. L.
- Date : 03/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 111
- Formats : PDF