Document IIF

Conducteurs de courant locaux HTS SIS100 : performance cryogénique.

SIS100 HTS local current leads. Cryogenic performance.

Numéro : pap. n. 0093

Auteurs : DATSKOV V., BLEILE A., HESS G., et al.

Résumé

In SIS100 accelerator cryostat system the major reduction of the heat load via more than 500 local current leads 250A will be done by use of the HTS materials. Modern 2G HTS tapes provide low thermal conductivity and high current density with heat-sink at the temperature below 70K. For FAIR project at GSI we developed a new heat-sink technique on the base of special epoxy. Cryogenic performance of the local current leads heat-sink was tested at 4K and 60K. Test data and analysis are provided.

Documents disponibles

Format PDF

Pages : 5 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : SIS100 HTS local current leads. Cryogenic performance.
  • Identifiant de la fiche : 30021750
  • Langues : Anglais
  • Source : Cryogenics 2017. Proceedings of the 14th IIR International Conference: Dresden, Germany, Mai 15-19, 2017.
  • Date d'édition : 15/05/2017
  • DOI : http://dx.doi.org/10.18462/iir.cryo.2017.0093

Liens


Voir d'autres communications du même compte rendu (71)
Voir le compte rendu de la conférence